Function library
Function blocks
3.5.25 Dead band (DB)
3−159
l
EDSVS9332P−EXT DE 2.0
3.5.25 Dead band (DB)
Purpose
The dead band element is used to set interfering influences around zero, e.g. interferences on analog
input voltages, to digital zero.
D B 1
D B 1 - O U T
D B 1 - I N
C 0 6 2 3
C 0 6 2 2
± 1 9 9 , 9 9 %
C 0 6 2 1
C 0 6 2 0
Fig. 3−113 Dead band element (DB1)
Signal
Source Note
Name Type DIS DIS format CFG List Lenze
DB1−IN a C0623 dec [%] C0622 1 1000
DB1−OUT a Limited to ±199.99 %
Function
l The dead band is parameterised under C0621.
l The gain is set under C0620.
C0621
C0620
DB1IN
DB1OUT
Fig. 3−114 Dead band and gain