Lenze EVS9332xP Manual de usuario Pagina 306

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 334
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 305
Function library
Function blocks
3.5.67 Variable table − target position/position values (VTPOS)
3−278
l
EDSVS9332P−EXT DE 2.0
Signal Source Note
Name Type DIS DIS format CFG List
VTPOS−IN1 ph C1351/1 dec [inc] C1350/1 3
VTPOS−IN2 ph C1351/2 dec [inc] C1350/2 3
VTPOS−IN3 ph C1351/3 dec [inc] C1350/3 3
VTPOS−IN4 ph C1351/4 dec [inc] C1350/4 3
VTPOS−IN5 ph C1351/5 dec [inc] C1350/5 3
VTPOS−IN6 ph C1351/6 dec [inc] C1350/6 3
VTPOS−IN7 ph C1351/7 dec [inc] C1350/7 3
VTPOS−IN8 ph C1351/8 dec [inc] C1350/8 3
VTPOS−IN9 ph C1351/8 dec [inc] C1350/9 3
VTPOS−IN10 ph C1351/10 dec [inc] C1350/10 3
VTPOS−OUT1 ph
... ...
VTPOS−OUT104 ph
Function
A total of 104 table positions are available.
l Enter fixed target position values via C1301/x.
60 table positions (VTPOS−No1 ... VTPOS−No60) are available.
Subcodes (C1301/1 ... C1301/60) define the table position number.
l Enter variable target position values via VTPOS−INx.
10 table positions (VTVEL−No61 ... VTVEL−No70) are available.
Signal input via function blocks.
The target position value must be transmitted to the table positions before the
corresponding program set starts and accesses these values.
l Enter target position values of FB TEACH1.
30 table positions (VTPOS−No71 ... VTPOS−No100) are available.
l Enter target position values via touch probe.
4 table positions (VTPOS−No101 ... VTPOS−No104) are available.
l C1380 displays the target position values (in units) on the table positions.
Select table position (C1380/1 ... C1380/104) with subcode.
l C1381 displays the target position values (in inc) on the table positions.
Select table position (C1381/1 ... C1381/104) with subcode.
l The conversion from target position [units] to target position [inc] is performed according to
the formula:
Targetposition[inc] + Targetposition[units] @
65536[incńr] @ gearnominator
Feedconst.[unitsńr] @ geardenominator
Tip!
Entries into the processing table are only required if FB inputs are used.
Vista de pagina 305
1 2 ... 301 302 303 304 305 306 307 308 309 310 311 ... 333 334