Function library
Function blocks
3.5.62 Multi−axis synchronisation (SYNC1)
3−261
l
EDSVS9332P−EXT DE 2.0
Synchronisation time
In addition to certain mains connection and initialisation time of the controller, the FB SYNC1 also
requires a synchronisation time.
The synchronisation time depends on
l the baud rate of the system bus (CAN−SYNC),
l the starting time (reception of the first SYNC telegram / signal),
l the time between the SYNC telegrams,
l the SYNC correction factor (C0363),
l the operating mode of the FB SYNC1.