Index table
15
Appendix
15.1
L
15.1−4
EDSPM−TXXX−9.0−11/2009
Index ImportantPossible settingsName
SelectionLenze
I1402
h
¿
Index is only available in the modular
system
8.3−3
1 COB−ID used by
RxPDO 3
512 385 {1} 2047 Defining the individual identifiers for
process data object 3
2 Transmisson type 255
0 {1} 255 Defining the transmission mode
0 ... 240 Process data update on sync telegram
transmission
The input data are accepted on sync
telegram transmission.
241
... 254
Reserved
255 Process data update on occurrence of an event Every received value is accepted
I1403
h
¿
Index is only available in the modular
system
8.3−3
1 COB−ID used by
RxPDO 4
830 385 {1} 2047 Defining the individual identifiers for
process data object 4
2 Transmisson type 255
0 {1} 255 Defining the transmission mode
0 ... 240 Process data update on sync telegram
transmission
The input data are accepted on sync
telegram transmission.
241
... 254
Reserved
255 Process data update on occurrence of an event Every received value is accepted
I1404
h
¿
Index is only available in the modular
system
8.3−3
1 COB−ID used by
RxPDO 5
1024 385 {1} 2047 Defining the individual identifiers for
process data object 5
2 Transmisson type
255 0 {1} 255 Defining the transmission mode
0 ... 240 Process data update on sync telegram
transmission
The input data are accepted on sync
telegram transmission.
241
... 254
Reserved
255 Process data update on occurrence of an event Every received value is accepted
I1405
h
¿
Index is only available in the modular
system
8.3−3
1 COB−ID used by
RxPDO 6
1080 385 {1} 2047 Defining the individual identifiers for
process data object 6
2 Transmisson type 255
0 {1} 255 Defining the transmission mode
0 ... 240 Process data update on sync telegram
transmission
The input data are accepted on sync
telegram transmission.
241
... 254
Reserved
255 Process data update on occurrence of an event Every received value is accepted
I1406
h
¿
Index is only available in the modular
system
8.3−3
1 COB−ID used by
RxPDO 7
1152 385 {1} 2047 Defining the individual identifiers for
process data object 7
2 Transmisson type 255
0 {1} 255 Defining the transmission mode
0 ... 240 Process data update on sync telegram
transmission
The input data are accepted on sync
telegram transmission.
241
... 254
Reserved
255 Process data update on occurrence of an event Every received value is accepted