Lenze EPM−T9XX Modular system Manual de usuario Pagina 289

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 544
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 288
System bus (CAN) / CANopen
Commissioning examples
11
Commissioning
11.1
11.1.2
L
11.1−5
EDSPM−TXXX−9.0−11/2009
When using the communication profile CANopen
1. Adapt the basic identifiers for the process data object 1.
Set PDO1−Rx via index 1400
h
, and subindex 1 to 770.
Set PDO1−Tx via index 1800
h
, and subindex 1 to 769.
2. Make a "reset node" by setting the index I2358
h
= 1. The settings are
accepted.
Setting of the baud rate and node address:
CANopen Baud rate
Coding switch value [kbit/s]
80 1000
81 500
82 250
83 125
84 100
85 50
86 20
87 10
88 800
Bold print = Lenze setting
1. Switch the CAN gateway module voltage supply off.
2. Use the coding switch to set the required baud rate.
Select value 91.
3. Switch the CAN gateway module voltage supply on.
The LEDs ER, RD and BA are blinking with a frequency of 1 Hz.
4. LEDs ER and BA go off after 5 seconds, and the set baud rate is stored.
5. Now set the node address 2 with the coding switch.
6. The set node address will be accepted after 5 seconds.
LED RD goes off.
The CAN gateway module changes to Pre−Operational status.
) Note!
The node address can be changed any time with the coding
switch. The setting is accepted after switching on the supply
voltage.
Vista de pagina 288
1 2 ... 284 285 286 287 288 289 290 291 292 293 294 ... 543 544

Comentarios a estos manuales