Lenze · E94AYCEP communication module (POWERLINK MN/CN) · Communication Manual · DMS 6.0 EN · 02/2014 · TD17 90
11 Parameter reference
11.2 Parameters of the communication module for slot MXI1
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C13219
C13225
Parameter | Name:
C13219 | EPL device type MN
Data type: UNSIGNED_32
Index: 11356 = 0x2C5C
EPL index: See subcodes
The code contains the device type ID of the declared EPL nodes. Each subcode corresponds to an EPL node with node
ID = subcode number.
When being in the configured status, the values must be identical with the device types stored locally in each EPL
node under C13030
.
Subcodes Lenze setting Info EPL index
C13219/1 0 Managing Node 0x1F84.0xF0
C13219/2 0 Diagnostics device 0x1F84.0xFD
C13219/3 0 router 0x1F84.0xFE
Read access Write access CINH PLC-STOP No transfer PDO_MAP_RX PDO_MAP_TX COM MOT
Parameter | Name:
C13225 | EPL MN: Max. user data RPDO
Data type: UNSIGNED_16
Index: 11350 = 0x2C56
EPL index: See subcodes
The code defines the reserved user data length of the PRes frames. Each subcode number corresponds to an EPL
node with the same node ID.
The subcode describes the PRes frames received. The value must be within the limits of 36 ... 1490 bytes.
The values are upper limit values for the total size of the PDO mappings which must be defined each one of the
codes C13231
... C13240 for PRes frames received.
In the configured state, the values stored for the EPL nodes must be identical to the corresponding C13072
entries.
C13066
must have an identical value in all EPL nodes of the network.
Setting range (min. value | unit | max. value)
0 Byte 1490
Subcodes Lenze setting Info EPL index
C13225/1 0 byte Managing Node 0x1F8D.0xF0
C13225/2 0 byte Diagnostics device 0x1F8D.0xFD
C13225/3 0 byte router 0x1F8D.0xFE
Read access Write access CINH PLC-STOP No transfer PDO_MAP_RX PDO_MAP_TX COM MOT