3 Product description
3.4 Terminals and interfaces
15
Lenze · E94AYCEP communication module (POWERLINK MN/CN) · Communication Manual · DMS 6.0 EN · 02/2014 · TD17
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
3.4 Terminals and interfaces
[3-2] E94AYCEP communication module (POWERLINK)
E94YCEP001A
X210 External voltage supply of the communication
module
• 2-pole connector with screw connection
External voltage supply
( 34)
X211 POWERLINK port 1
X212 POWERLINK port 2
• RJ45-sockets
• each with 2 LED status displays for diagnostics
POWERLINK connection
( 30)
Status displays at the RJ45 sockets (X211, X212)
( 53)
S233 DIP switch for setting the node address (Node ID)
Node address setting
( 36)
MS
ME
BS
BE
DE
LED status displays for diagnostic purposes
Module status displays
( 51)
Fieldbus status displays
( 52)