Lenze · E94AYCEP communication module (POWERLINK MN/CN) · Communication Manual · DMS 6.0 EN · 02/2014 · TD17 68
10 Error messages
10.2 POWERLINK error messages
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
0x18266 98918 EL_EPL_COM_CRC Faulty Ethernet frames (CRC error) have been detected.
Causes & remedy:
• see error description
EPL: Defective telegram (CRC) detected [0x00c88266]
( 65)
Codes:
• C13131/3
/ C14131/3 (monitoring threshold)
• C13891/4
/ C14891/4 (error response)
• C13131/1
/ C14131/1 (error counter)
0x38266 229990 QL_EPL_COM_CRC
0x48266 295526 WL_EPL_COM_CRC
0x68266 426598 I__EPL_COM_CRC
0x18267 98919 EL_EPL_MN_LOSS_
CN
The MXI connection to the Servo Drive 9400 is interrupted or a node
has failed.
Causes & remedy:
• see error description
EPL: Lost connection to 9400 [0x00c83100]
( 62)
EPL: Failure of a network node [0x00c88267]
( 65)
Codes:
• C13891/5
/ C14891/5 (error response)
• C13132
/ C14132 (CN: link interruptions)
0x38267 229991 QL_EPL_MN_LOSS_
CN
0x48267 295527 WL_EPL_MN_LOSS_
CN
0x68267 426599 I__EPL_MN_LOSS_
CN
0x18283 98947 EL_EPL_ADDRESS_
MN
An invalid IP address has been assigned by the Managing Node via
POWERLINK or set as Node ID.
OR:
The address setting of the Managing Node (Node ID = ’240’) has
been assigned several times.
Causes & remedy:
• see error description
EPL: Invalid address selected [0x00c88261]
( 64)
EPL: MN address assigned double [0x00c88283]
( 66)
Codes:
•see Node address setting
( 36)
•see Settings and displays in the »Engineer«
( 38)
0x38283 230019 QL_EPL_ADDRESS_
MN
0x48283 295555 WL_EPL_ADDRESS_
MN
0x68283 426627 I__EPL_ADDRESS_
MN
Error number Name Description
hex dec