Lenze · E94AYCEP communication module (POWERLINK MN/CN) · Communication Manual · DMS 6.0 EN · 02/2014 · TD17 38
6 Commissioning
6.3 Settings and displays in the »Engineer«
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
6.3 Settings and displays in the »Engineer«
Setting / display Description
General General information on the node type or the synchronisation of the
application
EPL address (project) Setting of the POWERLINK address (node ID: C13044
/ C14044)
• If the address ’240’ (Managing Node) is set here, only "Application
synchronised via Powerlink" can be activated in the general settings.
• The "Managing Node node" supports max. 50 nodes.
Current EPL device address Display of the current POWERLINK device address (C13042
/ C14042)
EPL host name The DNS-compatible host name (C13045
/ C14045) has to be non-
ambiguous within the network domain.
The device name ...
• consists of max. 15 characters ([A ... Z], [a ... z], [0 ... 9], [ - ]);
• starts with a letter;
• ends with a letter or a digit.
EPL IP address The IP address (C13000
/ C14000) is created from the POWERLINK address
(Node ID): 192.168.100.[C13044
/ C14044]
EPL MAC address Display of the MAC address (C13004
/ C14004)
Open/close advanced
settings
Here, the POWERLINK communication can be reset.
Comentarios a estos manuales