Lenze PLC Designer V2.x Manual de usuario Pagina 332

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 336
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 331
PLC Designer V2.x| Lenze Application Samples
The L_SSC_Scaling.lib library
L_SSC_UnitToSpeed - conversion block (for 9400 device series)
332 L 1.3 EN - 07/2012
20.22 L_SSC_UnitToSpeed - conversion block (for 9400 device series)
This FB converts the transferred speed parameters of the 9400 controller to an internal
speed value.
Inputs
Outputs
Identifier/data type Information/possible settings
diSpeedIn_e4
DINT
Speed in [unit/s]
Selection in "e4" view (fixed point with four decimal positions)
scAxisData
SSC_Axis_logic
Machine parameters
Identifier/data type Information/possible settings
diSpeedOut_s
DINT
Velocity as speed in [rpm] 15000 rpm 2
26
= 67108864
xLimit
BOOL
"Output signal is limited" status
TRUE: The output signal is limited to the representable value range.
xError
BOOL
"Error" status signal
FALSE No error
TRUE The conversion could not be carried out without errors.
Vista de pagina 331
1 2 ... 327 328 329 330 331 332 333 334 335 336

Comentarios a estos manuales

Sin comentarios