Lenze PLC Designer V2.x Manual de usuario Pagina 272

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 336
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 271
PLC Designer V2.x| Lenze Application Samples
The L_S8S_Drive82SMD.lib library
L_S8S_ActuatorSpeed - actuation of the 8400 SMD controller
272 L 1.3 EN - 07/2012
15 The L_S8S_Drive82SMD.lib library
This chapter describes the function blocks of the L_S8S_Drive82SMD. function library. The
function blocks of this function library serve to parameterise the 8200 SMD Lenze
frequency inverter.
15.1 L_S8S_ActuatorSpeed - actuation of the 8400 SMD controller
This FB serves to actuate the 8400 SMD controller.
Inputs
Outputs
Further information on the internal interfaces of the controller can be found in
the Operating Instructions (BA)_ESMD_CAN-Frequency_Inverter for the 8200
SMD:
Section CANopen | Detailed assignments
Identifier/data type Information/possible settings
xOptional
BOOL
Optional setting for the CAN node
FALSE Normal operation (transmission and reception via PDO)
TRUE The CAN node is set to the "Optional" mode to be able to receive
PDOs.
byNodeNumber
BYTE
Node number
byMasterNumber
BYTE
Interface number (1 ... 4)
Identifier/data type Information/possible settings
scDriveStatus Structural data regarding the drive status
xInternalControlActiv
BOOL
TRUE: Internal control active
Vista de pagina 271
1 2 ... 267 268 269 270 271 272 273 274 275 276 277 ... 335 336

Comentarios a estos manuales

Sin comentarios