PLC Designer V2.x| Lenze Application Samples
The L_SCS_DriveECS.lib library
L_SCS_PosiShaft - actuation of the ECS servo system
262 L 1.3 EN - 07/2012
Assignment of the process data from the controller:
13.3.2.2 Monitor data words from the controller (tx_par1 and tx_par2)
The monitor data words "tx_par1" and "tx_par2" can be assigned via control bits in
control word Ctrl1 with different display values:
ƒ Control bit 0 ("Ctrl1-Func1")
ƒ Control bit 1 ("Ctrl1-Func2")
ƒ Control bit 2 ("Ctrl1-Func4")
The following assignment of the monitor data words can be set via the control bits:
Word 1 Word 2 DWord (word 3 + word 4)
LOW byte HIGH byte LOW byte HIGH byte LOW word HIGH word
Byte 1 Byte 2 Byte 3 Byte 4 Byte 5 Byte 6 Byte 7 Byte 8
Status word Stat1 Status word Stat2 tx_par1 tx_par2
Control bits 0..2
in the control
word
Ctrl1 [binary]
Monitor data word
tx_par1 tx_par2
...000 Actual position (2
16
== 1 position encoder revolution)
...001 FollowErr (2
16
== 1 position encoder revolution)
...010 Actual speed value nact
Scaling: 214 == C0011 (maximum
speed)
Current torque Mact
Scaling: 214 == C0057 (Maximum torque calculated)
...011 Not assigned
...100 Not assigned
...101 Fault number DCTRL_wStat (C0150)
Bit assignment: see code list of the ECS device
...110 Profile generator status (C3066)
Bit assignment: see code list of the
ECS device
Not assigned
...111 AIn1 DigIn
Bit assignment:
Bit 0 ... 12: Image of analog input
Bit 13, 14, 15: 0 (no function)
DigIn
Bit assignment:
Bit 0 (X6/DI1): Image digital input 1
Bit 1 (X6/DI2): Image digital input 2
Bit 2 (X6/DI3): Image digital input 3
Bit 3 (X6/DI4): Image digital input 4
Bit 4 ... 15: 0 (no function)