1.3 EN - 07/2012 L 273
PLC Designer V2.x| Lenze Application Samples
The L_S8S_Drive82SMD.lib library
L_S8S_ActuatorSpeed - actuation of the 8400 SMD controller
15.1.1 Structure S8S_DriveControl - actuation to the controller
The bit assignment in the software application is identical to the bit assignment in the
controller.
Identifier/data type Control bits in the controller
Bit Identifier Meaning
xJog1
BOOL
0JOG1 Setpoint selection 1
xJog2
BOOL
1JOG2 Setpoint selection 2
xCwCcw
BOOL
2 DCTRL1-CW/CCW Define direction of rotation of the motor
• TRUE: CW rotation active (clockwise)
• FALSE: CCW rotation active (counter-
clockwise)
xQSP
BOOL
3DCTRL1-QSP Activate quick stop
xFreeBit04
BOOL
4 Not assigned
xFreeBit05
BOOL
5 Not assigned
xFreeBit06
BOOL
6 Not assigned
xFreeBit07
BOOL
7 Not assigned
xFreeBit08
BOOL
8 Not assigned
xEnable
BOOL
9DCTRL1-CINH Activate FB
xFreeBit10
BOOL
10 Not assigned
xErrorReset
BOOL
11 DCTRL1-TRIP-RESET Reset error
xFreeBit12
BOOL
12 Not assigned
xFreeBit13 13 Not assigned
xFreeBit14 14 Not assigned
xFreeBit15 15 Not assigned
rNset
REAL
Speed