Extending sample projects - adding devices
Creating a control configuration - EtherCAT bus system
52
Lenze · Commissioning of Lenze drives · 1.3 EN - 06/2014
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
2. Add an EtherCAT slave below the EtherCAT master.
Manually using the Add Device command in the context menu of the CANopen
master
Select a field device from the selection list. You can only select devices the CANopen
device description files of which have been imported in the »PLC Designer«.
The »PLC Designer« provides a "fieldbus scan" during which the devices connected to the
fieldbus are automatically detected.
More information can be found in the section "Lenze specificationsEtherCAT control
technology" of the online help for the »PLC Designer« and in the EtherCAT
communication manual (KHB)- Commissioning & configuration.
Repeat the Add Device command until all slaves connected to the fieldbus are included
in the control configuration.