The L_LCB_LogicControlBasic library
L_LCB_Speed_nToNorm_r - signal converter
134
Lenze · Commissioning of Lenze drives · 1.3 EN - 06/2014
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
13.14 L_LCB_Speed_nToNorm_r - signal converter
This function converts a 32 bit input signal into a 32 bit percentage signal.
Input
Output signal
L_LCB_Speed_nToNorm_r REAL 0- 100.0 %
13.15 L_LCB_Speed_rToNorm_n - signal converter
This function converts the input signal transferred to a 32 bit signal of the REAL data type.
Input
Output signal
L_LCB_Speed_rToNorm_n 0 -2
30
= 1073741824
Function library: L_LCB_LogicControlBasic
Runtime software licence: LPC 1x00 MPC 1x00 MPC 2xx0 MPC 3x00
L_LCB_Speed_nToNorm_r
DINT diIn_n L_LCB_Speed_nToNorm_r
Identifier/data type Information/possible settings
diIn_n
DINT
Input signal in [%] 100 % 2
30
= 1073741824
Function library: L_LCB_LogicControlBasic
Runtime software licence: LPC 1x00 MPC 1x00 MPC 2xx0 MPC 3x00
L_LCB_Speed_rToNorm_n
REAL rIn_r L_LCB_Speed_rToNorm_n
Identifier/data type Information/possible settings
rIn_r
REAL
Input signal 0-100.0 %