Lenze · Commissioning of Lenze drives · 1.3 EN - 06/2014 143
The L_LCB_LogicControlBasic library
L_LCB_SetSpeed - speed value conversion
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
13.25 L_LCB_SetSpeed - speed value conversion
This FB converts a velocity to a speed on the basis of the machine parameters transmitted and
provides them at the output dnSpeedOut_s for further processing within the function block
interconnection.
Inputs
Outputs
Function library: L_LCB_LogicControlBasic
Runtime software licence: LPC 1x00 MPC 1x00 MPC 2xx0 MPC 3x00
L_LCB_SetSpeed
REAL rSpeedInUnits diSpeedOut_s DINT
L_LCB_SetAxisData -
machine parameters
scAxisData xLimit BOOL
xError BOOL
eError L_LCB_Error
Identifier/data type Information/possible settings
rSpeedInUnits
REAL
Speed value in units
scAxisData
L_LCB_SetAxisData -
machine parameters
Machine parameters
Identifier/data type Information/possible settings
diSpeedOut_s
DINT
Output of the velocity as speed
in [rpm] 15000 rpm 2
26
= 67108864
xLimit
BOOL
"Output signal is limited" status
TRUE: The output signal is limited to the representable value range
±214748.3647.
xError
BOOL
"Error" status signal
FALSE Conversion carried out without errors
TRUE Error during the conversion
eError
L_LCB_Error
Error number, error code