The L_LCB_LogicControlBasic library
L_LCB_GetPosition - conversion block
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
13.21 L_LCB_GetPosition - conversion block
This FB converts the input signal transmitted to a position signal.
Inputs
Outputs
Function library: L_LCB_LogicControlBasic
Runtime software licence: LPC 1x00 MPC 1x00 MPC 2xx0 MPC 3x00
L_LCB_GetPosition
DINT diPosIn_p rPositionOutUnits REAL
L_LCB_SetAxisData -
machine parameters
scAxisData xError BOOL
eError L_LCB_Error
Identifier/data type Information/possible settings
diPosIn_p
DINT
Position in [increments]
Scaling: 1 encoder revolution 2
16
increments (or according to scAxisData)
scAxisData
L_LCB_SetAxisData -
machine parameters
Machine parameters
Identifier/data type Information/possible settings
rPositionOutUnits
REAL
Position value
Display of the input signal dnPosIn_p in the real unit of the machine.
xError
BOOL
"Error" status signal at the function block
FALSE Conversion carried out without errors
TRUE Error during the conversion
eError
L_LCB_Error
Error number, error code