The L_LCB_LogicControlBasic library
L_LCB_GetSpeed - conversion block
140
Lenze · Commissioning of Lenze drives · 1.3 EN - 06/2014
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
13.22 L_LCB_GetSpeed - conversion block
This FB converts the input speed transmitted to a speed value.
Inputs
Outputs
Function library: L_LCB_LogicControlBasic
Runtime software licence: LPC 1x00 MPC 1x00 MPC 2xx0 MPC 3x00
L_LCB_GetSpeed
DINT diSpeedIn_s rSpeedOutUnits REAL
L_LCB_SetAxisData -
machine parameters
scAxisData xError BOOL
eError L_LCB_Error
Identifier/data type Information/possible settings
diSpeedIn_s
DINT
Speed in [rpm] Scaling: 15000 rpm 2
26
= 67108864
scAxisData
L_LCB_SetAxisData -
machine parameters
Machine parameters
Identifier/data type Information/possible settings
rSpeedOutUnits
REAL
Speed value
xError
BOOL
"Error" status signal
FALSE Conversion carried out without errors
TRUE Error during the conversion
eError
L_LCB_Error
Error number, error code