Lenze PLC Designer R3-x Manual de usuario Pagina 115

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 159
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 114
Lenze · Commissioning of Lenze drives · 1.3 EN - 06/2014 115
The L_LCB_LogicControlBasic library
L_LCB_Error
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
13.2 L_LCB_Error
The L_DCO_Error type describes possible error messages that can be generated at the eError output
of the function block of the L_DCO_DriveControl Basic library.
All error messages are of the L_LCB_ERROR data type
13.3 L_LCB_AXIS_REF
This function block instance is a logic drive in the application.
Every Logic axis implemented in the control configuration is an extended instance of
L_LCB_AXIS_REF. A manual instancing of this function block is not required.
Via this FB, the application is provided with the process data of the connected logic axis.
L_LCB_AXIS_REF is an extension of the FB L_DCO_AXIS_REF_BASE
.
Inputs
Identifier Error number
(dec)
Description
L_LCB_NO_ERROR 0 No error
L_LCB_AXIS_IS_NO_AXIS_REF 20101 Connected Axis_REF instance is invalid
L_LCB_CON_DRIVE_INVALID 20102 Invalid drive identification of L_LCB_LOGICDEVICE
type
L_LCB_AXISDATA_INVALID 20110 The connected machine parameters are invalid.
L_LCB_AXIS_REF
UDINT udiTimeOut uiDeviceID UINT
USINT usiChannel uiNetID UINT
ARRAY[1.. 5] OF
L_DCO_SdoData
aSDOReadData xCommunicationOK BOOL
ARRAY[1..5] OF
L_DCO_SdoData
aSDOWriteData eCommunicationState L_DCO_CommState
ARRAY[1.. 16] OF WORD awReceiveData AxisName STRING
ARRAY[1.. 16] OF WORD awTransmitData
L_LCB_LOGICDEVICE
eLogicDevice
L_LCB_AxisData AxisDataDrive
Identifier Data type Initialisation Information/possible settings
udiTimeOut UDINT 10000 Timeout period for SDO communication
usiChannel USINT 1 SDO channel to be used
aSdoReadData ARRAY[1.. 5] OF
L_DCO_SdoData
0 Exchange for SDO communication (internal use)
aSdoWriteData ARRAY[1..5] OF
L_DCO_SdoData
0 Exchange for SDO communication (internal use)
awReceiveData ARRAY[1.. 16] OF
WORD
0 Interface for the process data received by the controller.
awTransmitData ARRAY[1.. 16] OF
WORD
0 Interface for the process data transmitted to the
controller.
Vista de pagina 114
1 2 ... 110 111 112 113 114 115 116 117 118 119 120 ... 158 159

Comentarios a estos manuales

Sin comentarios