L-force | PLC Designer
Compiler Errors and Warnings
DMS 3.2 EN 02/2011 TD29 637
4900
"Invalid type for conversion"
You are using a type conversion which is not supported by the currently chosen
codegenerator.
4901
"Internal error: Overflow in array access!"
The array bounds are to large for a 32-bit-variable. Reduce the array index range.
5100
"<Name> (<Zahl>): Expression too complex. No more registers available"
The named expression is to complex to be handled by the available registers. Please
try to reduce the expression by using interim variables.