L-force | PLC Designer
The Resources
408 DMS 3.2 EN 02/2011 TD29
Category: The category to which the particular log entry belongs. The following four
categories are possible:
User action: The user has carried out an Online action (typically from the Online
menu).
Internal action: An internal action has been executed in the Online layer (e.g.
Delete Buffers or Init debugging).
Status change: The status of the runtime system has changed (e.g. from Running
to Break, if a breakpoint is reached).
Exception: An exception has occurred, e.g. a communication error.
Description: The type of action. User actions have the same names as their
corresponding menu commands; all other actions are in English and have the same
name as the corresponding OnlineXXX() function.
Info: This field contains a description of an error that may have occurred during an
action. The field is empty if no error has occurred.
System time: The system time at which the action began, to the nearest second.
Relative time: The time measured from the beginning of the Online session, to the
nearest millisecond.
Duration: Duration of the action in milliseconds.
8.6.2 Menu Log
When the log window has the input focus, the menu option Log appears in the menu
bar instead of the items 'Extras' and 'Options'.
The menu includes the following items:
Load… An external log file *.log can be loaded and displayed using the standard file
open dialog.
The log that is present in the project will not be overwritten by the command. If the
log window is closed and later opened again, or a new Online session is started then
the version that is loaded will again be replaced by the project log.