17 Restrictions of the drive dimensioning
17.10 Displacement of the M-n characteristic
432
Lenze · Drive Solution Designer · Manual · DMS 4.2 EN · 12/2013 · TD23
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
17.10 Displacement of the M-n characteristic
If the max. available output voltage on the inverter is lower than the rated motor voltage, field
weakening already starts below the rated motor speed.
The output voltage on the inverter depends on the mains voltage.
Depending on the max. output voltage on the inverter, the available torque decreases.
In overboost operation (M > M
N
), this effect is particularly distinctive.
Possible causes are:
Mains undervoltage
Voltage drop on filters, chokes. The components are only considered in DSD if they are man-
datory for operation.
Voltage drop on long motor cables
The operating voltages of the inverter and motor (U
mot
>U
mains
) are not optimally assigned,
e. g. 460 V motor on the inverter with 400 V mains supply.
[17-4] Maximum and continuous torques
Note!
Only relevant for inverter-motor combinations which are not adjusted to each other as
regards voltage (output voltage of inverter < motor voltage).
Motor characteristic 360 V mains voltage
Motor characteristic 400 V mains voltage
Motor characteristic 440 V mains voltage