Lenze · Drive Solution Designer · Manual · DMS 4.2 EN · 12/2013 · TD23 357
11 Drive Dimensioning
11.7 Motor components
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
11.7 Motor components
11.7.1 Feedback selection
When the selection is made, DSD checks whether
the design of the feedback system is compatible with the selected motor,
the function of the feedback system is compatible with the selected inverter,
the inverter may be operated without feedback.
Tip!
You can also configure feedback systems for motors which act on slave drives. They there-
fore do not have to be compatible to the inverter that controls the motor.
The following criteria must be checked manually:
Accuracies, resolutions, limit frequencies, max. permissible speeds etc.
The limit frequency at the inverter input can be exceeded if the feedback system outputs a
too high pulse frequency due to the combination of number of increments and max. speed.