Lenze · Drive Solution Designer · Manual · DMS 4.2 EN · 12/2013 · TD23 237
8 Motion design
8.2 MotionDesigner
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Structure of the ASCII file
Comply with the following conditions when creating the ASCII file. Thus, errors can be prevented
during the import. Error messages during import
( 238)
Condition Description
The parameters in the ASCII file must
be arranged in columns.
Separate table columns using semicolons, tabulators or spaces.
Each table column has to contain a
heading.
• The title is the unit of the quantity to be transmitted.
• Example: "[s]" or "time [s]", "[m/s]" or "speed [m/s]", "[kg]" or "mass
[kg]".
• Indicate the quantity when being without a unit.
• Examples: [BRK], [CINH].
• Set unit/quantity in squared brackets, e.g. [t].
Arrangement, number and identity
of the parameters in the ASCII file
and in the Object area of the Mo-
tionDesigner must comply with each
other.
DSD reads the table columns from the left to the right. The parameters in
the Object area must be arranged accordingly from the top to the button.
• The data of the motion profile must be defined in the first two table col-
umns:
1. table column (X axis): Time [s]
2. table column (Y axis): Speed [m/s] (translatory) or speed [rpm] (rota-
ry).
The data must be consistent and
have valid value ranges.
• Table lines must be complete. No values should be missing.
• Mass must not have any negative values.
• Decimal numbers must not contain any characters.
• Decimals must be written with comma or point.
In case of digital signals, the states must be indicated with "1" (High) and
"0" (Low).
• An activated brake (BRK) or a set controller inhibit (CINH) is displayed
as "1".
• A deactivated brake (BRK) or non-set controller inhibit (CINH) is dis-
played as "0".
During the import, other programs
must not access the ASCII file.