Lenze DSD Manual de usuario Pagina 178

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 496
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 177
7Applications
7.19 Fan
178
Lenze · Drive Solution Designer · Manual · DMS 4.2 EN · 12/2013 · TD23
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Required torque of the fan
From the data entered and the load characteristic selected the DSD calculates the required torque.
[7-174] Load characteristics of the fan
Calculation of the torque for a quadratic load characteristic (M n²):
[7-175] Equation 3: Torque for a quadratic load characteristic
Calculation of the torque for a constant load characteristic (M constant):
[7-176] Equation 4: Torque for a constant load characteristic
Tip!
Further equations to complete the calculations required for an application can be found in
the chapter "Basic calculations
". ( 68)
The host computer "Energy efficiency fan/pump" serves to compare the energy de-
mand in an inverter-controlled and mechanically controlled system.
Constant characteristic (M constant)
Square-law characteristic (M n²)
Rated point of the fan
M
n
0
1
2
M
App
M
N
n
N
η
Vlt
---------
2
J
add
α+
=
M
App
M
N
J
add
α)(+=
Vista de pagina 177
1 2 ... 173 174 175 176 177 178 179 180 181 182 183 ... 495 496

Comentarios a estos manuales

Sin comentarios