8 Motion design
8.3 Predefined motion profile according to operating mode
272
Lenze · Drive Solution Designer · Manual · DMS 4.2 EN · 12/2013 · TD23
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
8.3.3 Intermittent operation S3, S4, S5
The intermittent operation consists of a sequence of identical cycles, each of which including an op-
erating time with constant load and a downtime.
Starting and braking times as well as inertias are characteristics of the respective operating mode:
S3: The starting current is irrelevant for the motor heating.
S4: The starting process is thermally relevant in addition.
S5: The brake reaction is additionally relevant.
[8-11] Motion profile for operating mode S3
t
BRK = 1
CINH = 1
t
acc
t
dec
Description
t Cycle time, corresponds to the duration of the load phase.
t
acc
Acceleration time required by the drive until the constant load condition is reached.
t
dec
Deceleration time required by the drive until standstill.
BRK Brake, BRK = 1: brake active
CINH Controller inhibit, CINH = 1: controller inhibit active