7Applications
7.18 Pump
174
Lenze · Drive Solution Designer · Manual · DMS 4.2 EN · 12/2013 · TD23
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Required torque of the pump
From the data entered and the load characteristic selected the DSD calculates the required torque.
[7-168] Load characteristics of the pump
Calculation of the torque for a quadratic load characteristic (M n²):
[7-169] Equation 3: Torque for a quadratic load characteristic
Calculation of the torque for a constant load characteristic (M constant):
[7-170] Equation 4: Torque for a constant load characteristic
Tip!
Further equations to complete the calculations required for an application can be
found in the chapter "Basic calculations
". ( 68)
The host computer "Energy efficiency fan/pump" serves to compare the energy de-
mand in an inverter-controlled and mechanically controlled system.
Constant characteristic (M constant)
Square-law characteristic (M n²)
Rated point of the pump
M
n
0
1
2
M
App
M
N
n
N
η
Pmp
-------------
2
J
add
α+
=
M
App
M
N
J
add
α)(+=