Drive PLC
Appendix
8.5 System error messages
8−9
L
DrivePLC DE 6.0
System error message Possible settings/response
Lenze setting ü setting possible
Available in
No. Display Source Meaning
Code TRIP Message Warning FAIL−
QSP
Off Drive
PLC
Servo
PLC
ECSxA
x089 PL MCTRL Error during rotor position adjustment ü ü
x091 EEr FWM External monitoring activated via DCTRL C0581 ü ü ü ü ü ü
x105 H05 internal Internal error (memory) ü ü ü
x107 H07 internal Internal error (power stage) ü ü
x108 H08 internal Extension board not connected correctly or not
supported by program
ü ü
x110 H10 FWM Temperature sensor error: heatsink tempera-
ture
C0588 ü ü ü
x111 H11 FWM Temperature sensor error: temperature inside
the controller
ü ü ü
FIF−CAN / CAN−AUX communication error:
x122 CE11
FIF−CAN1 FIF−CAN1_IN (monitoring time can be set under
C2457/1)
C0591 ü ü ü
CANaux1 CANaux1_IN (monitoring time can be set under
C2457/1)
C2481 ü ü ü
x123 CE12
FIF−CAN2 FIF−CAN2_IN (monitoring time can be set under
C2457/2)
C0592 ü ü ü
CANaux2 CANaux2_IN (monitoring time can be set under
C2457/2)
C2482 ü ü ü
x124 CE13
FIF−CAN3 FIF−CAN3_IN (monitoring time can be set under
C2457/3)
C0593 ü ü ü
CANaux3 CANaux3_IN (monitoring time can be set under
C2457/3)
C2483 ü ü ü
x125 CE14
FIF−CAN FIF−CAN BUS−OFF status
(too many faulty telegrams received)
C0595 ü ü ü
FIF−CAN FIF−CAN BUS−OFF status
(too many faulty telegrams received)
C2484 ü ü ü
x126 CE15 FIF−CAN Communication error of the gateway function
(C0370, C0371) via FIF−CAN
C2485 ü ü ü
x190 nErr MCTRL Speed out of tolerance margin (C0576) C0579 ü ü ü ü ü ü
x200 NMAX MCTRL Maximum speed exceeded (C0596) ü ü
Time−out (see task configuration):
x201 overrun Task1
internal
Task with ID 2
2)
ü ü ü ü ü
x202 overrun Task2 Task with ID 3
x203 overrun Task3 Task with ID 4
x204 overrun Task4 Task with ID 5
x205 overrun Task5 Task with ID 6
x206 overrun Task6 Task with ID 7
x207 overrun Task7 Task with ID 8
x208 overrun Task8 Task with ID 9
x219 overrun Cycl.−T internal Time−out in cyclic task (PLC_PRG, ID 1)
2)
ü ü ü ü ü
x: 0 = TRIP, 1 = Message, 2 = Warning, 3 = FAIL−QSP
2)
In DDS adjustable under Project W Exception response