Lenze DDS Target 9300 Servo PLC V8.x Manual de usuario

Busca en linea o descarga Manual de usuario para Hardware Lenze DDS Target 9300 Servo PLC V8.x. Lenze DDS Target 9300 Servo PLC V8.x User Manual Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir

Indice de contenidos

Pagina 1 - PLC Developer Studio

LManualGlobal Drive9300 Servo PLCGlobal DrivePLC Developer StudioShow/Hide Bookmarks

Pagina 2 - Important note:

9300 Servo PLCPreface and general information 1−4l9300 Servo PLC EN 5.11.2.2 Node numbersThe system blocks of the 9300 Servo PLC carry the following n

Pagina 3

2.12 MCTRL_MotorControl (node number 131)9300 Servo PLCSystem blocks 2−94L9300 Servo PLC EN 5.12.12.17.19 NMAX − speed monitoring (maximum speed excee

Pagina 4

9300 Servo PLCSystem blocks2.13 MCTRL_AUX_HighResFeedback (node number 181) 2−95L9300 Servo PLC EN 5.12.13 MCTRL_AUX_HighResFeedback (node number 181)

Pagina 5

2.14 STATEBUS_IO (node number 51)9300 Servo PLCSystem blocks 2−96L9300 Servo PLC EN 5.12.14 STATEBUS_IO (node number 51)The state bus is a bus system

Pagina 6

9300 Servo PLCSystem blocks2.15 SYSTEM_FLAGS (system flags, node number 151) 2−97L9300 Servo PLC EN 5.12.15 SYSTEM_FLAGS (system flags, node number 15

Pagina 7

2.15 SYSTEM_FLAGS (system flags, node number 151)9300 Servo PLCSystem blocks 2−98L9300 Servo PLC EN 5.1SYSTEM_bTogCycleTaskThis system flag toggles wi

Pagina 8

9300 Servo PLCAppendix3.1 PLC functionality 3−99L9300 Servo PLC EN 5.13 Appendix3.1 PLC functionalityField Number DescriptionInputs Digital1 Input for

Pagina 9

3.2 Extendability/networking9300 Servo PLCAppendix 3−100L9300 Servo PLC EN 5.13.2 Extendability/networking59 3971728889LECOM A/BlUVTSzZyYSH PRGpPaR2

Pagina 10 - 9300 Servo PLC

9300 Servo PLCAppendix3.3 Memories 3−101L9300 Servo PLC EN 5.13.3 MemoriesThe below table gives you an overview of the memories available:Memory Size

Pagina 11

9300 Servo PLCAppendix 3−102L9300 Servo PLC EN 5.13.3.1 Retain memoryIn the retain memory the values of the retain variables are stored safe from powe

Pagina 12

9300 Servo PLCAppendix 3−103L9300 Servo PLC EN 5.13.3.2 Persistent memoryIn the persistent memory 32 bytes of data can be stored safe from power failu

Pagina 13

9300 Servo PLCPreface and general information 1−5l9300 Servo PLC EN 5.11.2.3 Access via system variablesYou can use the system variables of a system b

Pagina 14 - High Word Low Word 031

9300 Servo PLCAppendix 3−104L9300 Servo PLC EN 5.13.3.3 Downloading dataIn DDS (as of version 2.0) it is possible to attach a file to your project who

Pagina 15

9300 Servo PLCAppendix3.4 System POUs 3−105L9300 Servo PLC EN 5.13.4 System POUsSystem POUs are POUs of the "program" type which accept the

Pagina 16

3.5 System error messages9300 Servo PLCAppendix 3−106L9300 Servo PLC EN 5.13.5 System error messagesThe history buffer (C0168/x) stores error messages

Pagina 17

9300 Servo PLCAppendix3.5 System error messages 3−107L9300 Servo PLC EN 5.13.5.1 Overview of system error messages, error sources and reactionsSystem

Pagina 18

3.5 System error messages9300 Servo PLCAppendix 3−108L9300 Servo PLC EN 5.1System error message Possible settings/response Lenze setting  setting po

Pagina 19

9300 Servo PLCAppendix3.5 System error messages 3−109L9300 Servo PLC EN 5.1System error message Possible settings/response Lenze setting  setting po

Pagina 20

3.5 System error messages9300 Servo PLCAppendix 3−110L9300 Servo PLC EN 5.13.5.2 Response and its effects on the driveResponse  EffectOperating unit

Pagina 21

9300 Servo PLCAppendix 3−111L9300 Servo PLC EN 5.13.5.4 Causes and remediesFault messageDescription Cause RemedyNo. Display−−− −−− No fault − −0011 OC

Pagina 22

9300 Servo PLCAppendix 3−112L9300 Servo PLC EN 5.1Fault message RemedyCauseDescriptionNo.RemedyCauseDescriptionDisplayx058 OH8 Motor temperature via i

Pagina 23

9300 Servo PLCAppendix 3−113L9300 Servo PLC EN 5.1Fault message RemedyCauseDescriptionNo.RemedyCauseDescriptionDisplay0079 PI Fault during parameter i

Pagina 24

9300 Servo PLCPreface and general information 1−6l9300 Servo PLC EN 5.11.2.5 Definition of inputs/outputsThe application program is connected with the

Pagina 25

9300 Servo PLCAppendix 3−114L9300 Servo PLC EN 5.1Fault message RemedyCauseDescriptionNo.RemedyCauseDescriptionDisplayx089 PL Error during rotor posit

Pagina 26

9300 Servo PLCAppendix 3−115L9300 Servo PLC EN 5.1Fault message RemedyCauseDescriptionNo.RemedyCauseDescriptionDisplayx240 ovrTransQueue"Free CAN

Pagina 27

9300 Servo PLCAppendix 3−116L9300 Servo PLC EN 5.13.5.5 Fault analysis via the fault memoryThe fault memory of the PLC consists of 8 memory locations

Pagina 28

9300 Servo PLCAppendix 3−117L9300 Servo PLC EN 5.1Fault resetThe current fault can be reset by a TRIP−RESET e.g. via C0043:Code LCDPossible settingsIn

Pagina 29

9300 Servo PLCAppendix 3−118L9300 Servo PLC EN 5.13.5.6 Fault analysis via the LED display of the PLCTwo LEDs at the front of the PLC indicate the con

Pagina 30

9300 Servo PLCAppendix3.6 Code table 3−119L9300 Servo PLC EN 5.13.6 Code tableHow to read the code table:Column Abbreviation MeaningCode C016812…8Code

Pagina 31 - AIF_wControl

3.6 Code table9300 Servo PLCAppendix 3−120L9300 Servo PLC EN 5.1Code InformationPossible settingsLCDCode InformationSelectionLenzeLCDC0011 Nmax 3000 M

Pagina 32

9300 Servo PLCAppendix3.6 Code table 3−121L9300 Servo PLC EN 5.1Code InformationPossible settingsLCDCode InformationSelectionLenzeLCDC0030 DFOUT const

Pagina 33 - AOUT1_nOut_a

3.6 Code table9300 Servo PLCAppendix 3−122L9300 Servo PLC EN 5.1Code InformationPossible settingsLCDCode InformationSelectionLenzeLCDC0061 Heatsink te

Pagina 34

9300 Servo PLCAppendix3.6 Code table 3−123L9300 Servo PLC EN 5.1Code InformationPossible settingsLCDCode InformationSelectionLenzeLCD[C0085] Mot Ls 

Pagina 35

9300 Servo PLCPreface and general information 1−7l9300 Servo PLC EN 5.11.2.6 Linking of system blocks with DDSThe system blocks required must be expli

Pagina 36

3.6 Code table9300 Servo PLCAppendix 3−124L9300 Servo PLC EN 5.1Code InformationPossible settingsLCDCode InformationSelectionLenzeLCD[C0086] Mot type

Pagina 37

9300 Servo PLCAppendix3.6 Code table 3−125L9300 Servo PLC EN 5.1Code InformationPossible settingsLCDCode InformationSelectionLenzeLCD[C0086] Mot type

Pagina 38

3.6 Code table9300 Servo PLCAppendix 3−126L9300 Servo PLC EN 5.1Code InformationPossible settingsLCDCode InformationSelectionLenzeLCD[C0086] Mot type

Pagina 39

9300 Servo PLCAppendix3.6 Code table 3−127L9300 Servo PLC EN 5.1Code InformationPossible settingsLCDCode InformationSelectionLenzeLCD[C0089] Mot frequ

Pagina 40

3.6 Code table9300 Servo PLCAppendix 3−128L9300 Servo PLC EN 5.1Code InformationPossible settingsLCDCode InformationSelectionLenzeLCDC0108 FCODE (gain

Pagina 41

9300 Servo PLCAppendix3.6 Code table 3−129L9300 Servo PLC EN 5.1Code InformationPossible settingsLCDCode InformationSelectionLenzeLCDC0128 TAU motor 5

Pagina 42

3.6 Code table9300 Servo PLCAppendix 3−130L9300 Servo PLC EN 5.1Code InformationPossible settingsLCDCode InformationSelectionLenzeLCDC0150 Status word

Pagina 43

9300 Servo PLCAppendix3.6 Code table 3−131L9300 Servo PLC EN 5.1Code InformationPossible settingsLCDCode InformationSelectionLenzeLCDC0157 Stat. FreeB

Pagina 44

3.6 Code table9300 Servo PLCAppendix 3−132L9300 Servo PLC EN 5.1Code InformationPossible settingsLCDCode InformationSelectionLenzeLCD[C0173] UG limit

Pagina 45

9300 Servo PLCAppendix3.6 Code table 3−133L9300 Servo PLC EN 5.1Code InformationPossible settingsLCDCode InformationSelectionLenzeLCDC0209 DL info 3gD

Pagina 46

9300 Servo PLCPreface and general information 1−8l9300 Servo PLC EN 5.11.2.7 Signal types and scalingsMost inputs and outputs of Lenze function blocks

Pagina 47

3.6 Code table9300 Servo PLCAppendix 3−134L9300 Servo PLC EN 5.1Code InformationPossible settingsLCDCode InformationSelectionLenzeLCDC0356 CAN boot−up

Pagina 48

9300 Servo PLCAppendix3.6 Code table 3−135L9300 Servo PLC EN 5.1Code InformationPossible settingsLCDCode InformationSelectionLenzeLCDC0362 Sync cycleg

Pagina 49

3.6 Code table9300 Servo PLCAppendix 3−136L9300 Servo PLC EN 5.1Code InformationPossible settingsLCDCode InformationSelectionLenzeLCDC0383 LifeTimeFac

Pagina 50

9300 Servo PLCAppendix3.6 Code table 3−137L9300 Servo PLC EN 5.1Code InformationPossible settingsLCDCode InformationSelectionLenzeLCDC0431 DFIN TP EDG

Pagina 51

3.6 Code table9300 Servo PLCAppendix 3−138L9300 Servo PLC EN 5.1Code InformationPossible settingsLCDCode InformationSelectionLenzeLCDC0471 FCODE 32bit

Pagina 52

9300 Servo PLCAppendix3.6 Code table 3−139L9300 Servo PLC EN 5.1Code InformationPossible settingsLCDCode InformationSelectionLenzeLCDC0504PLC memory:

Pagina 53

3.6 Code table9300 Servo PLCAppendix 3−140L9300 Servo PLC EN 5.1Code InformationPossible settingsLCDCode InformationSelectionLenzeLCDC0545 PH offset 0

Pagina 54

9300 Servo PLCAppendix3.6 Code table 3−141L9300 Servo PLC EN 5.1Code InformationPossible settingsLCDCode InformationSelectionLenzeLCDC0585 MONIT OH8 3

Pagina 55

3.6 Code table9300 Servo PLCAppendix 3−142L9300 Servo PLC EN 5.1Code InformationPossible settingsLCDCode InformationSelectionLenzeLCDC0603 MONIT CE5 3

Pagina 56

9300 Servo PLCAppendix3.6 Code table 3−143L9300 Servo PLC EN 5.1Code InformationPossible settingsLCDCode InformationSelectionLenzeLCDC0863 DIS: INx di

Pagina 57

9300 Servo PLCSystem blocks 2−9L9300 Servo PLC EN 5.12 System blocksThe following sections inform about the system blocks of the basic unit.

Pagina 58

3.6 Code table9300 Servo PLCAppendix 3−144L9300 Servo PLC EN 5.1Code InformationPossible settingsLCDCode InformationSelectionLenzeLCDC0868 DIS: OUTx.W

Pagina 59

9300 Servo PLCAppendix3.6 Code table 3−145L9300 Servo PLC EN 5.1Code InformationPossible settingsLCDCode InformationSelectionLenzeLCDC0907 DIS: digita

Pagina 60

3.6 Code table9300 Servo PLCAppendix 3−146L9300 Servo PLC EN 5.1Code InformationPossible settingsLCDCode InformationSelectionLenzeLCDC1191 Char.: temp

Pagina 61

9300 Servo PLCAppendix3.6 Code table 3−147L9300 Servo PLC EN 5.1Code InformationPossible settingsLCDCode InformationSelectionLenzeLCDC2120 AIF: Contro

Pagina 62

3.6 Code table9300 Servo PLCAppendix 3−148L9300 Servo PLC EN 5.1Code InformationPossible settingsLCDCode InformationSelectionLenzeLCDC2354 XCAN sel.ad

Pagina 63

9300 Servo PLCAppendix3.6 Code table 3−149L9300 Servo PLC EN 5.1Code InformationPossible settingsLCDCode InformationSelectionLenzeLCDC2375 XCAN Tx mod

Pagina 64

9300 Servo PLCAppendix 3−150L9300 Servo PLC EN 5.13.6.1 Temporary codesCodes C2500 and C2501 are temporary codes, i.e. the data does not occupy any E

Pagina 65

9300 Servo PLCAppendix 3−151L9300 Servo PLC EN 5.1ParametersCode Data type Access InfoSubcode Possible settings PresettingC0504 − R / W Activate/deact

Pagina 66

9300 Servo PLCAppendix 3−152L9300 Servo PLC EN 5.1Auto−increment accessThe four data bytes are always read/written through "auto−increment access

Pagina 67

9300 Servo PLCAppendix3.7 Attribute table 3−153L9300 Servo PLC EN 5.13.7 Attribute tableIf you want to create your own programs, you will need the inf

Pagina 68

2.1 AIF1_IO_AutomationInterface (node number 41)9300 Servo PLCSystem blocks 2−10L9300 Servo PLC EN 5.12.1 AIF1_IO_AutomationInterface (node number 41)

Pagina 69

3.7 Attribute table9300 Servo PLCAppendix 3−154L9300 Servo PLC EN 5.1AccessDataIndexCodeConditionLCM−R/WDecimalpositionDLFormatDTDADShexdecCodeC0037 2

Pagina 70

9300 Servo PLCAppendix3.7 Attribute table 3−155L9300 Servo PLC EN 5.1AccessDataIndexCodeConditionLCM−R/WDecimalpositionDLFormatDTDADShexdecCodeC0126 2

Pagina 71

3.7 Attribute table9300 Servo PLCAppendix 3−156L9300 Servo PLC EN 5.1AccessDataIndexCodeConditionLCM−R/WDecimalpositionDLFormatDTDADShexdecCodeC0363 2

Pagina 72

9300 Servo PLCAppendix3.7 Attribute table 3−157L9300 Servo PLC EN 5.1AccessDataIndexCodeConditionLCM−R/WDecimalpositionDLFormatDTDADShexdecCodeC0575 2

Pagina 73

3.7 Attribute table9300 Servo PLCAppendix 3−158L9300 Servo PLC EN 5.1AccessDataIndexCodeConditionLCM−R/WDecimalpositionDLFormatDTDADShexdecCodeC1191 2

Pagina 74

9300 Servo PLCIndex4−159L9300 Servo PLC EN 5.14 IndexAAbsolute value encoder, monitoring , 2−90 Additional torque setpoint, 2−57 Addresses, absolute

Pagina 75

9300 Servo PLCIndex4−160L9300 Servo PLC EN 5.1EE2PROM−buffered memory, 3−101 Earth fault, monitoring, 2−74 Encoder cable monitoring, 2−42 Error mes

Pagina 76 - 2.12.17 Monitoring

9300 Servo PLCIndex4−161L9300 Servo PLC EN 5.1MMaster frequency input, 2−36 Master frequency output, 2−43 Maximum speed, 2−59 MCTRL_AUX_HighResFeed

Pagina 77

9300 Servo PLCIndex4−162L9300 Servo PLC EN 5.1OOC1 − short−circuit monitoring, 2−74 OC2 − earth−fault monitoring, 2−74 OC5 − I x t overload monitori

Pagina 78

9300 Servo PLCIndex4−163L9300 Servo PLC EN 5.1System blocks, 2−9 Absolute addresses, 1−5 AIF_IO_Management, 2−23 Inputs_AIF_Management, 2−23 Outpu

Pagina 79

9300 Servo PLCSystem blocks2.1 AIF1_IO_AutomationInterface (node number 41) 2−11L9300 Servo PLC EN 5.1System variablesVariable Data type Signal type A

Pagina 80

2.1 AIF1_IO_AutomationInterface (node number 41)9300 Servo PLCSystem blocks 2−12L9300 Servo PLC EN 5.1User dataThe received 8 bytes of user data are a

Pagina 81

9300 Servo PLCSystem blocks2.1 AIF1_IO_AutomationInterface (node number 41) 2−13L9300 Servo PLC EN 5.1 2.1.2 Outputs_AIF1This SB is used as an interfa

Pagina 82

This documentation is valid for the following Lenze PLC devices:Type designation As of hardware version As of software version9300 Servo PLC EVS93XX−x

Pagina 83

2.1 AIF1_IO_AutomationInterface (node number 41)9300 Servo PLCSystem blocks 2−14L9300 Servo PLC EN 5.1System variablesVariable Data type Signal type A

Pagina 84 - J Warnings!

9300 Servo PLCSystem blocks2.2 AIF2_IO_AutomationInterface (node number 42) 2−15L9300 Servo PLC EN 5.12.2 AIF2_IO_AutomationInterface (node number 42)

Pagina 85

2.2 AIF2_IO_AutomationInterface (node number 42)9300 Servo PLCSystem blocks 2−16L9300 Servo PLC EN 5.1System variablesVariable Data type Signal type A

Pagina 86

9300 Servo PLCSystem blocks2.2 AIF2_IO_AutomationInterface (node number 42) 2−17L9300 Servo PLC EN 5.1 2.2.2 Outputs_AIF2This SB is used as an interfa

Pagina 87

2.2 AIF2_IO_AutomationInterface (node number 42)9300 Servo PLCSystem blocks 2−18L9300 Servo PLC EN 5.1System variablesVariable Data type Signal type A

Pagina 88

9300 Servo PLCSystem blocks2.3 AIF3_IO_AutomationInterface (node number 43) 2−19L9300 Servo PLC EN 5.12.3 AIF3_IO_AutomationInterface (node number 43)

Pagina 89

2.3 AIF3_IO_AutomationInterface (node number 43)9300 Servo PLCSystem blocks 2−20L9300 Servo PLC EN 5.1System variablesVariable Data type Signal type A

Pagina 90

9300 Servo PLCSystem blocks2.3 AIF3_IO_AutomationInterface (node number 43) 2−21L9300 Servo PLC EN 5.1 2.3.2 Outputs_AIF3This SB is used as an interfa

Pagina 91

2.3 AIF3_IO_AutomationInterface (node number 43)9300 Servo PLCSystem blocks 2−22L9300 Servo PLC EN 5.1System variablesVariable Data type Signal type A

Pagina 92

9300 Servo PLCSystem blocks2.4 AIF_IO_Management (node number 161) 2−23L9300 Servo PLC EN 5.12.4 AIF_IO_Management (node number 161)2.4.1 Inputs_AIF_M

Pagina 93

9300 Servo PLCContentsiL9300 Servo PLC EN 5.11 Preface and general information 1−1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Pagina 94

2.4 AIF_IO_Management (node number 161)9300 Servo PLCSystem blocks 2−24L9300 Servo PLC EN 5.1System variablesVariable Data type Signal type Address Di

Pagina 95

9300 Servo PLCSystem blocks2.4 AIF_IO_Management (node number 161) 2−25L9300 Servo PLC EN 5.1 2.4.2 Outputs_AIF_ManagementThis SB transfers commands a

Pagina 96

2.5 ANALOG1_IO (node number 11)9300 Servo PLCSystem blocks 2−26L9300 Servo PLC EN 5.12.5 ANALOG1_IO (node number 11)2.5.1 Inputs_ANALOG1 (analog input

Pagina 97

9300 Servo PLCSystem blocks2.5 ANALOG1_IO (node number 11) 2−27L9300 Servo PLC EN 5.1Terminal assignment Set via C0034 whether the input is to be use

Pagina 98

2.6 ANALOG2_IO (node number 12)9300 Servo PLCSystem blocks 2−28L9300 Servo PLC EN 5.12.6 ANALOG2_IO (node number 12)2.6.1 Inputs_ANALOG2 (analog input

Pagina 99

9300 Servo PLCSystem blocks2.7 DCTRL_DriveControl (node number 121) 2−29L9300 Servo PLC EN 5.12.7 DCTRL_DriveControl (node number 121)This SB controls

Pagina 100

2.7 DCTRL_DriveControl (node number 121)9300 Servo PLCSystem blocks 2−30L9300 Servo PLC EN 5.12.7.1 Inputs_DCTRLSystem variablesVariables Data type Si

Pagina 101

9300 Servo PLCSystem blocks2.7 DCTRL_DriveControl (node number 121) 2−31L9300 Servo PLC EN 5.12.7.3 Quick stop (QSP)The QSP function is used to stop t

Pagina 102 - 9300 Servo PLC / 932X / 933X

2.7 DCTRL_DriveControl (node number 121)9300 Servo PLCSystem blocks 2−32L9300 Servo PLC EN 5.12.7.5 Controller inhibit (CINH)This function sets "

Pagina 103

9300 Servo PLCSystem blocks2.7 DCTRL_DriveControl (node number 121) 2−33L9300 Servo PLC EN 5.12.7.7 Resetting TRIP (TRIP−RESET)This function resets an

Pagina 104

9300 Servo PLCContentsiiL9300 Servo PLC EN 5.12.7 DCTRL_DriveControl (node number 121) 2−29 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Pagina 105

2.7 DCTRL_DriveControl (node number 121)9300 Servo PLCSystem blocks 2−34L9300 Servo PLC EN 5.1Code LCDPossible settingsInfoLenze SelectionC0150 Status

Pagina 106 - 3.2 Extendability/networking

9300 Servo PLCSystem blocks2.7 DCTRL_DriveControl (node number 121) 2−35L9300 Servo PLC EN 5.12.7.9 Transfer of status/control word via AIFIf the cont

Pagina 107

2.8 DFIN_IO_DigitalFrequency (node number 21)9300 Servo PLCSystem blocks 2−36L9300 Servo PLC EN 5.12.8 DFIN_IO_DigitalFrequency (node number 21)2.8.1

Pagina 108

9300 Servo PLCSystem blocks2.8 DFIN_IO_DigitalFrequency (node number 21) 2−37L9300 Servo PLC EN 5.1Tip!The process image is newly created for every ta

Pagina 109

2.8 DFIN_IO_DigitalFrequency (node number 21)9300 Servo PLCSystem blocks 2−38L9300 Servo PLC EN 5.1Configuration of the digital frequency input signal

Pagina 110

9300 Servo PLCSystem blocks2.8 DFIN_IO_DigitalFrequency (node number 21) 2−39L9300 Servo PLC EN 5.1Transmission functionDFIN_nIn_v + f[Hz] @60Increme

Pagina 111

2.8 DFIN_IO_DigitalFrequency (node number 21)9300 Servo PLCSystem blocks 2−40L9300 Servo PLC EN 5.12.8.1.1 Technical data for the connection of X91234

Pagina 112

9300 Servo PLCSystem blocks2.8 DFIN_IO_DigitalFrequency (node number 21) 2−41L9300 Servo PLC EN 5.12.8.1.2 Touch probe (TP)Process: The current phase

Pagina 113

2.8 DFIN_IO_DigitalFrequency (node number 21)9300 Servo PLCSystem blocks 2−42L9300 Servo PLC EN 5.1Functional sequence1. The TP is activated via a sig

Pagina 114

9300 Servo PLCSystem blocks2.9 DFOUT_IO_DigitalFrequency (node number 22) 2−43L9300 Servo PLC EN 5.12.9 DFOUT_IO_DigitalFrequency (node number 22)2.9.

Pagina 115

9300 Servo PLCContentsiiiL9300 Servo PLC EN 5.13 Appendix 3−99 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Pagina 116

2.9 DFOUT_IO_DigitalFrequency (node number 22)9300 Servo PLCSystem blocks 2−44L9300 Servo PLC EN 5.1Configuration of the digital frequency output sign

Pagina 117

9300 Servo PLCSystem blocks2.9 DFOUT_IO_DigitalFrequency (node number 22) 2−45L9300 Servo PLC EN 5.1Configuration of the encoder constant The encoder

Pagina 118

2.9 DFOUT_IO_DigitalFrequency (node number 22)9300 Servo PLCSystem blocks 2−46L9300 Servo PLC EN 5.1Digital frequency output X10Technical dataConnecti

Pagina 119

9300 Servo PLCSystem blocks2.10 DIGITAL_IO (node number 1) 2−47L9300 Servo PLC EN 5.12.10 DIGITAL_IO (node number 1)2.10.1 Inputs_DIGITAL (digital inp

Pagina 120

2.10 DIGITAL_IO (node number 1)9300 Servo PLCSystem blocks 2−48L9300 Servo PLC EN 5.1 2.10.2 Outputs_DIGITAL (digital outputs)This SB conditions the d

Pagina 121

9300 Servo PLCSystem blocks2.11 FCODE_FreeCode (node number 141) 2−49L9300 Servo PLC EN 5.12.11 FCODE_FreeCode (node number 141)At Lenze, controller p

Pagina 122

2.11 FCODE_FreeCode (node number 141)9300 Servo PLCSystem blocks 2−50L9300 Servo PLC EN 5.1System variablesVariable Data type Signal type Address Disp

Pagina 123

9300 Servo PLCSystem blocks2.11 FCODE_FreeCode (node number 141) 2−51L9300 Servo PLC EN 5.1Note!The free code C0470 is stored under the same memory ad

Pagina 124

2.12 MCTRL_MotorControl (node number 131)9300 Servo PLCSystem blocks 2−52L9300 Servo PLC EN 5.12.12 MCTRL_MotorControl (node number 131)This SB contai

Pagina 125

9300 Servo PLCSystem blocks2.12 MCTRL_MotorControl (node number 131) 2−53L9300 Servo PLC EN 5.1The process image is created in the course of a fixed s

Pagina 126

9300 Servo PLCContentsivL9300 Servo PLC EN 5.1

Pagina 127

2.12 MCTRL_MotorControl (node number 131)9300 Servo PLCSystem blocks 2−54L9300 Servo PLC EN 5.1Variable NoteDisplayFormatDisplayCodeAddressSignal type

Pagina 128

9300 Servo PLCSystem blocks2.12 MCTRL_MotorControl (node number 131) 2−55L9300 Servo PLC EN 5.12.12.2 Outputs_MCTRLSystem variablesVariable Data type

Pagina 129

2.12 MCTRL_MotorControl (node number 131)9300 Servo PLCSystem blocks 2−56L9300 Servo PLC EN 5.12.12.3 Current controllerTip!Select a matching motor fr

Pagina 130

9300 Servo PLCSystem blocks2.12 MCTRL_MotorControl (node number 131) 2−57L9300 Servo PLC EN 5.12.12.4 Torque setpoint / additional torque setpointMCTR

Pagina 131

2.12 MCTRL_MotorControl (node number 131)9300 Servo PLCSystem blocks 2−58L9300 Servo PLC EN 5.12.12.5 Torque limitationVia MCTRL_nLoMLim_a and MCTRL_n

Pagina 132

9300 Servo PLCSystem blocks2.12 MCTRL_MotorControl (node number 131) 2−59L9300 Servo PLC EN 5.12.12.6 Maximum speedThe maximum speed (nmax) is set und

Pagina 133

2.12 MCTRL_MotorControl (node number 131)9300 Servo PLCSystem blocks 2−60L9300 Servo PLC EN 5.12.12.7 Speed controllerThe speed controller is designed

Pagina 134

9300 Servo PLCSystem blocks2.12 MCTRL_MotorControl (node number 131) 2−61L9300 Servo PLC EN 5.1Signal limitationIf the drive outputs the maximum torqu

Pagina 135

2.12 MCTRL_MotorControl (node number 131)9300 Servo PLCSystem blocks 2−62L9300 Servo PLC EN 5.12.12.9 Speed setpoint limitationThe speed setpoint limi

Pagina 136

9300 Servo PLCSystem blocks2.12 MCTRL_MotorControl (node number 131) 2−63L9300 Servo PLC EN 5.12.12.11 Quick stop (QSP)The QSP function is used to sto

Pagina 137

9300 Servo PLCPreface and general information 1−1l9300 Servo PLC EN 5.11 Preface and general information1.1 About this ManualThis Manual describes the

Pagina 138

2.12 MCTRL_MotorControl (node number 131)9300 Servo PLCSystem blocks 2−64L9300 Servo PLC EN 5.12.12.12 Field weakeningAdjusting the field weakening ra

Pagina 139

9300 Servo PLCSystem blocks2.12 MCTRL_MotorControl (node number 131) 2−65L9300 Servo PLC EN 5.12.12.14 Feedback systemsThe following codes can be used

Pagina 140

2.12 MCTRL_MotorControl (node number 131)9300 Servo PLCSystem blocks 2−66L9300 Servo PLC EN 5.12.12.15 Touch probe (TP)Process: The current phase valu

Pagina 141

9300 Servo PLCSystem blocks2.12 MCTRL_MotorControl (node number 131) 2−67L9300 Servo PLC EN 5.1Function sequence1. The TP is activated via a signal ch

Pagina 142

2.12 MCTRL_MotorControl (node number 131)9300 Servo PLCSystem blocks 2−68L9300 Servo PLC EN 5.12.12.16 Manual adaptation of motor dataIf you use a mot

Pagina 143

9300 Servo PLCSystem blocks2.12 MCTRL_MotorControl (node number 131) 2−69L9300 Servo PLC EN 5.1Code IMPORTANTPossible settingsLCDCode IMPORTANTSelecti

Pagina 144

2.12 MCTRL_MotorControl (node number 131)9300 Servo PLCSystem blocks 2−70L9300 Servo PLC EN 5.12.12.17 MonitoringThe 9300 Servo PLC comprises two inde

Pagina 145

9300 Servo PLCSystem blocks2.12 MCTRL_MotorControl (node number 131) 2−71L9300 Servo PLC EN 5.1The fault memory (C0168/x) stores the error messages wi

Pagina 146

2.12 MCTRL_MotorControl (node number 131)9300 Servo PLCSystem blocks 2−72L9300 Servo PLC EN 5.1Overview of system error messages of the motor controlE

Pagina 147

9300 Servo PLCSystem blocks2.12 MCTRL_MotorControl (node number 131) 2−73L9300 Servo PLC EN 5.1Response and effect on the driveResponse  EffectKeypad

Pagina 148

9300 Servo PLCPreface and general information 1−2l9300 Servo PLC EN 5.11.1.3 Pictographs in this ManualPictographsusedSignal wordsWarning of materiald

Pagina 149

2.12 MCTRL_MotorControl (node number 131)9300 Servo PLCSystem blocks 2−74L9300 Servo PLC EN 5.12.12.17.1 OC1 − short−circuit monitoringThis monitoring

Pagina 150

9300 Servo PLCSystem blocks2.12 MCTRL_MotorControl (node number 131) 2−75L9300 Servo PLC EN 5.12.12.17.3 OC5 − I x t overload monitoringErrorMonitorin

Pagina 151

2.12 MCTRL_MotorControl (node number 131)9300 Servo PLCSystem blocks 2−76L9300 Servo PLC EN 5.12.12.17.4 OC6/OC8 − I2 x t overload monitoring (current

Pagina 152

9300 Servo PLCSystem blocks2.12 MCTRL_MotorControl (node number 131) 2−77L9300 Servo PLC EN 5.1Forced ventilated or naturally ventilated motorsParamet

Pagina 153

2.12 MCTRL_MotorControl (node number 131)9300 Servo PLCSystem blocks 2−78L9300 Servo PLC EN 5.1Self−ventilated motorsDue to the construction, self−ven

Pagina 154

9300 Servo PLCSystem blocks2.12 MCTRL_MotorControl (node number 131) 2−79L9300 Servo PLC EN 5.1Calculate release time and I2 x t loadCalculate the rel

Pagina 155

2.12 MCTRL_MotorControl (node number 131)9300 Servo PLCSystem blocks 2−80L9300 Servo PLC EN 5.12.12.17.5 OU − overvoltage monitoringThis function moni

Pagina 156 - 9300 Servo PLC EN 5.1

9300 Servo PLCSystem blocks2.12 MCTRL_MotorControl (node number 131) 2−81L9300 Servo PLC EN 5.1Braking torque deratingWithout a braking system being c

Pagina 157

2.12 MCTRL_MotorControl (node number 131)9300 Servo PLCSystem blocks 2−82L9300 Servo PLC EN 5.12.12.17.6 LU − undervoltage monitoringThis function mon

Pagina 158

9300 Servo PLCSystem blocks2.12 MCTRL_MotorControl (node number 131) 2−83L9300 Servo PLC EN 5.12.12.17.7 LP1 − monitoring of the motor phasesThis moni

Pagina 159

9300 Servo PLCPreface and general information 1−3l9300 Servo PLC EN 5.11.2 System block introductionFor a long time, Lenze has followed the principle

Pagina 160

2.12 MCTRL_MotorControl (node number 131)9300 Servo PLCSystem blocks 2−84L9300 Servo PLC EN 5.12.12.17.8 OH − heatsink temperature monitoring (fixed)T

Pagina 161

9300 Servo PLCSystem blocks2.12 MCTRL_MotorControl (node number 131) 2−85L9300 Servo PLC EN 5.12.12.17.9 OH3 − motor temperature monitoring (fixed)Thi

Pagina 162

2.12 MCTRL_MotorControl (node number 131)9300 Servo PLCSystem blocks 2−86L9300 Servo PLC EN 5.12.12.17.10 OH4 − heatsink temperature monitoring (adjus

Pagina 163

9300 Servo PLCSystem blocks2.12 MCTRL_MotorControl (node number 131) 2−87L9300 Servo PLC EN 5.12.12.17.11 OH7 − motor temperature monitoring (adjustab

Pagina 164

2.12 MCTRL_MotorControl (node number 131)9300 Servo PLCSystem blocks 2−88L9300 Servo PLC EN 5.12.12.17.12 OH8 − motor temperature monitoring via T1, T

Pagina 165

9300 Servo PLCSystem blocks2.12 MCTRL_MotorControl (node number 131) 2−89L9300 Servo PLC EN 5.12.12.17.13 Sd2 − resolver monitoring for open circuitTh

Pagina 166

2.12 MCTRL_MotorControl (node number 131)9300 Servo PLCSystem blocks 2−90L9300 Servo PLC EN 5.12.12.17.14 Sd6 − motor temperature sensor monitoringThi

Pagina 167

9300 Servo PLCSystem blocks2.12 MCTRL_MotorControl (node number 131) 2−91L9300 Servo PLC EN 5.12.12.17.16 Sd8 − sin/cos encoder monitoring during oper

Pagina 168

2.12 MCTRL_MotorControl (node number 131)9300 Servo PLCSystem blocks 2−92L9300 Servo PLC EN 5.12.12.17.17 PL − monitoring of the rotor position adjust

Pagina 169

9300 Servo PLCSystem blocks2.12 MCTRL_MotorControl (node number 131) 2−93L9300 Servo PLC EN 5.12.12.17.18 nErr − speed monitoring (speed out of tolera

Comentarios a estos manuales