Lenze Global Drive PLC Developer Studio Manual de usuario Pagina 47

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 129
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 46
Drive PLC
System blocks
2.12 DCTRL_DriveControl (node number 121)
2−33
L
DrivePLC DE 6.0
Codes
Code LCD
Possible settings
Info
Lenze Selection
C0150 Status word 0
Status word, access via code and
FCODE C0150
0 Not assigned
1 Not assigned
2 Not assigned
3 Not assigned
4 Not assigned
5 Not assigned
6 Not assigned
7 PLC stopped
8 Controller status 1
9 Controller status 2
10 Controller status 3
11 Controller status 4
12 Warning active
13 Message active
14 Not assigned
15 Not assigned
Free bits (0 ... 6, 14, 15) can be
written via FCODE_C0150.
C0155 Status word 2 0
Extended status word, read only
0 Fail
1 Not assigned
2 Not assigned
3 Not assigned
4 Not assigned
5 PLC stopped
6 TRIP / QSP
7 Not assigned
8 Not assigned
9 Not assigned
10 Not assigned
11 Not assigned
12 Not assigned
13 Not assigned
14 Not assigned
15 Not assigned
Tip!
The assignment of the status word bits marked as "not assigned" depends on the AIF module used
and the set transfer profile (e.g.: DRIVECOM).