Function library
Function blocks
3−306
l
EDSVS9332K−EXT EN 4.0
C 1 1 2 3
C 1 1 2 2
C 1 1 2 1
C 1 1 2 0
X 4
X 5 - E 5
C L K
S Y N C 2
S Y N C 2 - S T A T
Signal Source Note
Name Type DIS DIS format CFG List Lenze
SYNC2−STAT d After completion of the synchronisation SYNC2−STAT switches
to HIGH.
If the synchronity is quit, SYNC2−STAT switches to LOW.
Tip!
l Communication via CAN bus
Use the function block SYNC2, when sending/receiving the data of the X or Y axis via the
CAN bus. Observe the calculating times of both function blocks (see chapter "Function
block description").
Enter the function block into the processing table when speed values are to be transferred
via the CAN bus. The signals of the CAN bus must not be guided via the function block FB
SYNC1 but must be used directly.
l If you use software versions >V2.2, please see the commissioning example Multi−axis
application" in part C of this Manual.