
Function library
Function blocks
3−109
l
EDSVS9332K−EXT EN 4.0
CONV2
C 0 9 4 7
C 0 9 4 8
C O N V 2 - I N
C O N V 2 - O U T
C O N V 2
C 0 9 4 5
C 0 9 4 6
C O N V 2 - D F O U T
FB_conv2
Fig. 3−79 Function block CONV2
Signal
Source Note
Name Type DIS DIS format CFG List Lenze
CONV2−IN a C0948 dec [%] C0947 1 1000
CONV2−OUT a − − − − − Limited to ±199.99 %
CONV2−DFOUT phd − − − − − Limited to ±29999 rpm
This function block is used to multiply or divide analog signals.
Conversion according to formula:
CONV2−OUT + CONV2−IN @
100%
15000 rpm
@
C0945
C0946
or
CONV2−DFOUT + CONV2−IN @
C0945
C0946
[rpm]
CONV3
C O N V 3
C O N V 3 - O U T
C O N V 3 - I N
C 0 9 5 3
C 0 9 5 2
C 0 9 5 0
C 0 9 5 1
C O N V 3 - D F O U T
Fig. 3−80 Function block CONV3
Signal
Source Note
Name Type DIS DIS format CFG List Lenze
CONV3−IN phd C0953 dec [rpm] C0952 4 1000
CONV3−OUT a − − − − − Limited to ±199.99 %
CONV3−DFOUT phd − − − − − Limited to ±29999 rpm
This function block is used to convert speed signals into analog signals.
Conversion according to formula:
CONV3−OUT + CONV3−IN @
100%
15000 rpm
@
C0950
C0951
or
CONV3−DFOUT + CONV3−IN @
C0950
C0951
[rpm]
Comentarios a estos manuales