Function library
Function blocks
3.2.86 Ramp function generator for angle signals (RFGPH2 and RFGPH3)
3−280
l
EDSVS9332K−EXT EN 4.0
Status signals
RFGPH2−RFG−I=0 = HIGH indicates that the output RFGPH2−OUT has reached the final value
selected (the output is not adjusted any more).
t
t
t
RFGPH2-RFG-0
RFGPH2-SET
RFGPH2-RFG-I=0
t
RFGPH2-RESET
RFGPH2-PHOUT
(Status)
(Control)
(Control)
9300kur016
RESET mode
Use C1074/1 (RFGPH2) and C1074/2 (RFGPH3) to set the status for the output RFGPHx−PHOUT
after a RESET command (RFGPHx−RESET = HIGH):
C1074/x RFGPHx−POUT
0 0
1 ACT
2 SET