Function library
Function blocks
3−110
l
EDSVS9332K−EXT EN 4.0
CONV4
C O N V 4
C O N V 4 - O U T
C O N V 4 - I N
C 0 9 5 8
C 0 9 5 7
C 0 9 5 5
C 0 9 5 6
C O N V 4 - D F O U T
Fig. 3−81 Function block CONV4
Signal
Source Note
Name Type DIS DIS format CFG List Lenze
CONV4−IN phd C0958 dec [rpm] C0957 4 1000
CONV4−OUT a − − − − − Limited to ±199.99 %
CONV4−DFOUT phd − − − − − Limited to ±29999 rpm
This function block is used to convert speed signals into analog signals.
Conversion according to formula:
CONV4−OUT + CONV4−IN @
100%
15000 rpm
@
C0955
C0956
or
CONV4−DFOUT + CONV3−IN @
C0955
C0956
[rpm]
CONV5
CONV5
CONV5-OUT
CONV5-IN
C0658
C0657
C0655
C0656
Fig. 3−82 Function block CONV5
Signal
Source Note
Name Type DIS DIS format CFG List Lenze
CONV5−IN a C0658 dec [%] C0657 1 1000
CONV5−OUT phd − − − − − Limited to ±29999 rpm
This function block is used to convert analog signals into speed signals.
Conversion according to formula:
CONV5−OUT + CONV5−IN @
15000 rpm
100%
@
C0655
C0656