Lenze · ApplicationTemplate · 1.3 EN - 04/2013 53
Working with the ApplicationTemplate
Integrating a machine module into the MMT
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
8.3 Integrating a machine module into the MMT
The machine module (created on the basis of the MM_EmptyModule template) has to be integrated
into the MachineModuleTree(MMT) to implement it in the ApplicationTemplate in a serviceable
state.
How to proceed:
1. Double-click the A10_MachineModuleTree folder in the device view.
• Double-click MMT (PRG).
Note: The programming language of MMT (PRG) is CFC (Continuous Function Chart).
•In the Tools dialog window, click the Block button.
• Create the new FB via drag-and-drop.
• Double-click the area of the FB. Click the button.
Use the Input assistance from the Application element...
• ...to assign the MFB_CrossCutter FB.
• ...to assign the CrossCutter instance.
Note: Go to the Input assistant and select the ; Insert with namespace prefix when
assigning the instance name.
2. Specify the relative address for the machine module.
•In the Tools dialog window, click the Input button.
• Add the new input at MM_Address
• Assign the relative address (example: 3).
3. Connect FBs MFB_MachineControl and MFB_CrossCutter to each other.
• Example (ApplicationTemplate Counter):
Note: After inserting a machine module, the processing order
of the machine modules
which results after inserting the further machine module is to be checked.
For changing the Processing order
, adapt the element number in the top right corner of
the corresponding machine module.
• For this, call the Processing order menu item in the context menu of the element