Lenze · ApplicationTemplate · 1.3 EN - 04/2013 33
Opening the ApplicationTemplate
Going online
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
7.3 Going online
In order to be able to establish an online connection to the controller, the communication settings
(Set active path) must be commissioned before. Establishing communication with the controller
( 13)
7.3.1 Compiling the project data
To compile the project data, select the BuildBuild menu command or press the <F11> function
key.
• If errors occur during the compilation, they are to be localised on the basis of the »PLC Designer«
error messages and corrected correspondingly. Recompile the project data afterwards.
• If no errors occur during the compilation, the »PLC Designer« project must be saved:
File Save project
7.3.2 Transferring the project to the control - "Log in"
The desired project must be transferred to the PLC device by "Logging in" to the controller: Call menu
command Online Log in.
7.4 Loading and starting the PLC program
• Load the PLC program to the controller: Call OnlineLoad menu command.
• Start the PLC program: Call OnlineStart menu command.
• As an alternative, you can execute the DebugStart menu command or press <F5>.
Tip!
In order to load a project automatically after a device is restarted, it can be defined as
"boot project".
Setting up the project as boot application
How to install the project as boot project:
1. Select the OnlineGenerate boot project for L-force Controller menu command.
Note!
To "log in" the PLC program must be error-free. For this it must be possible to execute the
BuildBuild (F11) menu command without an error message.