Architecture: The ApplicationTemplate in detail
Internal Control
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Program in machine module 2 ( TaskHighPriority = 2 ms):
9.17 Internal Control
The "Internal Control" function makes it possible to decouple a slave module from its master. This
is advisable during e.g. commissioning.
[9-29] Example MM_Module1: The Activate button activates the "Internal Control"
How to use the "Internal Control":
1. Call the A20_Visualisation folder, L_Main.
2. Activate the desired machine module for which the "Internal Control" is to be activated,
example: MM_Module1.
3. Click the Internal Control button for activation.
4. Enter the password by clicking into the text field that is now visible.
•Standard value: lenze
Confirm password entry with Enter.
IF Lock() THEN
For i:=0 TO 2000 by 1 DO
rACDOwn.aCAMData[i] := aCAMData[i];
END_FOR
Unlock()
IF NOT LockState() THEN
For i:=0 TO 2000 by 1 DO
aCAMData[i] := rACDModule1.aCAMData[i];
END_FOR
END_IF