Data transfer
DRIVECOM profile parameters
7
Feldbus-Baugruppe 2113 INTERBUS
7.6
7.6.7
L
7.6-33
EDSIBS-1.0-06/2003
7.6.7 DRIVECOM profile parameters
7.6.7.1 Process data description
The description is on page
( 7.6-5).
The description is on page
( 7.6-6).
The parameter enables or inhibits the PO data (output data for INTERBUS
master). By this, the consistency of the PO data is guaranteed.
Output data inhibit: 00000000
hex
Output data enable: FFFFF
hex
Every bit enables a process data byte!
If you change 6001
hex
, the changed process data bytes will be inhibited
automatically. That means, that the controller does not receive new control data
until index 6002
hex
enables the communication again.
Parameter name (Index) Subindex Data structure Data type
PO data description (6002
hex
) 0 R PBS (20
hex
)
All process data are enabled when the device is switched on (6002
hex
FFFFF
hex
)
PI data description (6000
hex
)
PO data description (6001
hex
)
PO data enable (6002
hex
)
Show/Hide Bookmarks