Lenze CANopen control technology Manual de usuario Pagina 30

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 105
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 29
Control technology | CANopen communication manual
Planning the CANopen network
Device specifications of the field devices
30 L DMS 4.2 EN 07/2011 TD17
6.2.1 Special features of the Servo Drives 9400
The parameter data channel 1 is always active.
The optional parameter data channels 2 ... 10 can be activated via the subcodes of the
codes Cxx372 and Cxx373.
If bit 31 is set (0x8nnnnnnn
hex
), the corresponding SDO server is deactivated.
In order to change the COB-ID of a currently active parameter data channel, you have
to first deactivate it and then activate it with a changed COB-ID. Both processes must
be rendered effective by a "Reset Node" command via C00002.
Basic identifier - 9400 Servo Drives
The default setting of the basic identifier is as follows:
1) When creating the sync transmit/receive identifier manually, observe the use of the emergency telegram because of
the same COB-ID.
SDO identifier Code
CANopen SDO server Rx identifier C00372: CAN on board
C13372: Module in slot 1
C14372: Module in slot 2
CANopen SDO server Tx identifier C00373: CAN on board
C13373: Module in slot 1
C14373: Module in slot 2
Object Direction Basic identifier
from the drive to the drive dec hex
NMT 0 0
Sync 1) 128 80
Emergency z 128 80
PDO1
(process data channel 1)
TPDO1
z 384 180
RPDO1
z 512 200
PDO2
(process data channel 2)
TPDO2
z 640 280
RPDO2
z 768 300
PDO3
(process data channel 3)
TPDO3
z 896 380
RPDO3
z 1024 400
PDO4
(process data channel 4)
TPDO4
z 1152 480
RPDO4
z 1280 500
SDO1
(parameter data channel 1)
TSDO1
z 1408 580
RSDO1
z 1536 600
SDO2 ... 10
(parameter data channel 2 ... 10)
TSDOx
z 1472 5C0
RSDOx
z 1600 640
Node guarding, heartbeat z 1792 700