Configuration
Basic configurations
2.2.4 Master frequency coupling
2−18
l
EDSVS9332S−EXT EN 2.0
2.2.4.3 Slave for master frequency bus
Purpose
The configuration C0005 = 6XXX for the setpoint bus serves to
l activate the phase control, which is upstream to the speed controller
l change the setpoint signal path to master frequency coupling for phase or speed−synchronous
operation
Resolver
R
Slave 1 Slave2
Factor
Resolver
R
SWI
ö,n controller
Master drive with
Master integrator and
Slave 0
X8
Encoder
X7
X10
Encoder
output
X6 X9 X10
Encoder
Encoder
output
X7 X8
X9
Resolver
R
Factor
X10
Encoder
Encoder
output
X7 X8
X9
ö,n controller ö,n controller
Fig. 2−1 Slave for master frequency bus