Application examples
4.3 Torque control with speed limitation (C0005 = 4000)
4−7
l
EDSVS9332S−EXT EN 2.0
4.3 Torque control with speed limitation (C0005 = 4000)
Tip!
The most important settings can be found in the menu: "Short Setup / Speed mode" of the operating
module or in the menu "Short setup / Speed mode" in Global Drive Control.
Enter motor type (contains all nameplate data of the motor)
C0173 xxx Enter UG limit (mains voltage)
C0086 000 Enter motor data manually
Enter maximum motor current
C0022 xxxA Determine Imax
Enter controller configuration
C0005 4000 Select torque control
C0025 xxx Enter feedback system
Speed setpoint settings
C0011 xxx rpm Determine max. speed
C0105 xxx s Set QSP deceleration time
Speed limitation
C0472/4 xxx % nmax Determine lower speed limit
Application parameters
C0070 xxx Vp n−controller
C0071 xxx Tn n−controller
Save parameters
C0003 xxx Save all parameters