Error messages
Communication entity generator
254
Lenze · Engineer · 2.13 EN - 10/2014
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Error during writing of parameter value {0} [CE94CAN0003]
Node with SYNC source property must be NMT master [CE94CAN0004]
Predefined connection set active [CE94CAN0005]
Response (Lenze setting printed in bold)
Error Warning Information
Cause Remedy
Parameter value could not be written to the code.
Response (Lenze setting printed in bold)
Error Warning Information
Cause Remedy
A special feature of the 9400 is that, when it is to send a
synchronisation object, it must be the NMT master at the
same time.
• Go to the network which is assigned to the device.
• Highlight the corresponding node in the Node tab.
• The node is enclosed in green.
• Select
Set NMT master from the context menu of the right
mouse button.
• The master node has a black triangle in the right
corner at the bottom.
Nodes
( 216)
Response (Lenze setting printed in bold)
Error Warning Information
Cause Remedy
Node is not connected to a CAN network. In the Settings
tab of the node, the control field Use Predefined
Connection Set was selected. During the compilation,
the settings for COB-IDs, SYNC, etc. were assigned in
accordance with CANopen.
This message is information for the user.