Defining the system functionality
Creating an interconnection via the electrical shaft
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
8.14.3 Virtual master/real master
Virtual master
[8-11] Example of a "virtual master" (with transfer of master value via extension module master frequency)
Real master
[8-12] Example of a "real master" (with master value transfer via extension module master frequency)
A drive in the interconnection performs
the tasks of the (virtual) master and is
simultaneously the first slave drive.
The master value formed by the "virtual
master" function within the part the plant
is transferred to the other slave drives via a
bus system or the digital frequency output.
d v
R
i
v
Virtual master /
Slave 1
X10: DFout
The master value is defined for a slave
drive in the interconnection by a real
master (e.g. external encoder).
This can be done e.g. via the digital
frequency input of the extension module
or via a bus system.
The master value (within the technology
application; if necessary, edited) is
transferred to the other slave drives via a
bus system or the digital frequency output.
d
v
d v
R1
R2
1
2
i
1
i
2
v
1
v
2
X10: DFout
Real master/
Slave 1
X9: DFin