Defining the system functionality
Function block editor (FB Editor)
152
Lenze · Engineer · 2.13 EN - 10/2014
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
[8-8] Example for adding an additional connection in the FB Editor (representation: Connection as line)
The procedure of extending the connection is independent of the representation format in
the FB Editor (valid for line/flag).
Scenario:
The existing connections (line)
are to be extended.
•Mouse-click + <Ctrl> on the desired end
point of the connection.
Move the copied end point of the
connection line to the desired FB input.
In the example of bTi8 to
bTi2 ).
Click the desired FB input to add the new
connection.
In the example of bTi2
An additional connection has been added
to the bTi2 by the bOut FB output.