Digital frequency extension module | Parameter setting & configuration
Parameter reference
Parameter list | C14075
44 L EDS94AYFLF EN 3.2 - 10/2010
C14075
C14076
C14077
C14080
Parameter | Name:
C14075 | Unit
Data type: VISIBLE_STRING
Index: 10500
d
= 2904
h
Subcodes Info
C14075/1 Unit for the position
C14075/2 Unit for the speed
; Read access Write access CINH PLC-STOP No transfer
Parameter | Name:
C14076 | Actual position DFOUT
Data type: INTEGER_32
Index: 10499
d
= 2903
h
Display range (min. value | unit | max. value)
-214748.3647 Unit 214748.3647
; Read access Write access CINH PLC-STOP No transfer Scaling factor: 10000
Parameter | Name:
C14077 | Actual speed DFOUT
Data type: INTEGER_32
Index: 10498
d
= 2902
h
Display range (min. value | unit | max. value)
-214748.3647 Unit/s 214748.3647
; Read access Write access CINH PLC-STOP No transfer Scaling factor: 10000
Parameter | Name:
C14080 | Resp. to freq. limit. DFOUT
Data type: UNSIGNED_8
Index: 10495
d
= 28FF
h
Digital frequency extension module in module receptacle MXI2:
Response when limit frequency for digital frequency output X10 is reached.
Is executed if the digital frequency reaches the limit value set in C14053
.
Selection list
(Lenze setting in bold)
1Fault
2Trouble
3 Quick stop by trouble
5 Warning
4 Warning locked
6 Information
0 No response
; Read access ; Write access CINH PLC-STOP No transfer