Digital frequency extension module | Parameter setting & configuration
Digital frequency output
Parameter setting
22 L EDS94AYFLF EN 3.2 - 10/2010
3.2 Parameter setting
Short overview of the parameters for the digital frequency output:
Note!
Depending on the module receptacle the digital frequency extension module is
plugged in, different code ranges are assigned to the parameters!
Module receptacle MXI1: Parameters are in the C130xx range
Module receptacle MXI2: Parameters are in the C140xx range
Parameter Info Lenze setting
Value Unit
C13050 C14050 Signal source DFOUT Application
C13051
C14051 No. of increments DFOUT 2048
C13052
C14052 Zero pulse offset DFOUT 0 Increments
C13053
C14053 Frequency limitation DFOUT 500 kHz
C13061
C14061 TP delay time DFOUT 0 μs
C13070 C14070 Speed at DFOUT - Incr./ms
C13071 C14071 Frequency at DFOUT - Hz
C13072 C14072 Position at DFOUT - Increments
C13080
C14080 Resp. to frequency limit. DFOUT Warning
Digital frequency extension module in module receptacle MXI1
Digital frequency extension module in module receptacle MXI2
Greyed out = display parameter