EDS94AYFLF EN 3.2 - 10/2010 L 27
Digital frequency extension module | Parameter setting & configuration
Digital frequency output
Parameter setting
3.2.5 Frequency limitation
In C13053
/ C14053 a frequency limitation can be set for the digital frequency output.
If the frequency is limited, a fault message is generated and the response set in C13080
/ C14080
is executed.
– At the same time the output DFOUT_bOutputFreqLimited of the system block
LS_DigitalFrequencyOutput is set to TRUE.
The hardware limits the digital frequency output to 500 kHz.
3.2.6 Touch probe
When the zero pulse occurs on track Z - Z
, a touch probe is triggered.
The corresponding signals to execute touch probe processing are available via the
system block LS_TouchProbeDFOUT.
In C13061
/ C14061 a delay time can be set for the touch probe.
If a touch probe has been triggered, the output DFOUT_bTouchProbeReceived is set to
TRUE for one cycle.
Tip!
Detailed information on touch probe processing can be found in the online
documentation for the controller in chapter "I/O terminalsTouch probe
detection".
Note!
• Due to the remainder processing implemented in the 4 kHz control cycle, only
settings ≥ 4 kHz are reasonable for frequency limitation!
• If the digital frequency input is directly connected to the digital frequency
output, the set frequency limitation is without function!