Lenze E94AYFLF Digital frequency module Manual de usuario Pagina 24

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 54
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 23
Digital frequency extension module | Parameter setting & configuration
Digital frequency output
Parameter setting
24 L EDS94AYFLF EN 3.2 - 10/2010
3.2.2 Number of increments and zero pulse offset
The number of increments set in C13051
/ C14051 defines e.g. the number of increment to
be output before a zero pulse is created.
Each zero pulse defines a covered "revolution" of the rotary transducer simulated by the
digital frequency output.
Within such a "revolution" (in the value range 0 ... 65535 increments) the zero pulse can
be shifted by setting a zero pulse offset in C13052
/ C14052.
A connection between absolute position and "revolution" is defined by setting the position,
as described in the following chapter "Position setting
". The position of a zero pulse within
a "revolution" remains unchanged.
Example - signal characteristic:
[3-2] Example: Signal characteristic with the zero pulse offset set to 39321 increments
6 Output of the encoder angle
The angle of rotation in [increments] derived from the encoder input is output as a frequency
signal after being evaluated with the set number of increments (C13051
/ C14051).
The output signal is integrated to a position value via a counter and made available to the
application via the output DFOUT_dnActualPos_p of the system block
LS_DigitalFrequencyOutput.
It is irrelevant for the output whether the encoder input is used as a load encoder, motor encoder,
or not used at all for the motor control.
7 Output of a speed signal of the application
The speed signal in [rpm] defined via the input DFOUT_dnSpeedSet_s of the system block
LS_DigitalFrequencyOutput is integrated and output as a frequency signal after being evaluated
with the set number of increments (C13051
/ C14051).
The output signal is integrated to a position value via a counter and made available to the
application via the output DFOUT_dnActualPos_p of the system block
LS_DigitalFrequencyOutput.
Selection Info
n Absolute position (DFOUT_dnActualPos_p, also takes into account each overflow of the encoder position)
o Position difference (is determined by Position setting
)
p Encoder position (in the value range 0 ... 65535 increments)
q Zero pulse offset (adjustable in C13052
/ C14052)
r Zero pulses
39321
65535
t
t
[Inc]
0
DFOUT_dnActualPos_p
Vista de pagina 23