Lenze E94AYFLF Digital frequency module Manual de usuario Pagina 43

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 54
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 42
EDS94AYFLF EN 3.2 - 10/2010 L 43
Digital frequency extension module | Parameter setting & configuration
Parameter reference
Parameter list | C14053
C14053
C14061
C14070
C14071
C14072
Parameter | Name:
C14053 | Frequency limitation DFOUT
Data type: UNSIGNED_16
Index: 10522
d
= 291A
h
Digital frequency extension module in module receptacle MXI2:
Limit frequency for digital frequency output X10
Frequency to which the digital frequency output is limited by the software.
If the limit value is reached, the response set in C14080
is executed.
In terms of the hardware, the digital frequency output is limited to 500 kHz.
If the digital frequency input is directly connected to the digital frequency output, the set frequency limitation
is functionless!
Note: Du to the remainder processing implemented in the 4 kHz control cycle, only settings 4 kHz are reasonable
for frequency limitation!
Frequency limitation
Setting range (min. value | unit | max. value) Lenze setting
1 kHz 500 500 kHz
; Read access ; Write access CINH PLC-STOP No transfer
Parameter | Name:
C14061 | TP delay time DFOUT
Data type: UNSIGNED_32
Index: 10514
d
= 2912
h
Digital frequency extension module in module receptacle MXI2:
Touch probe delay for digital frequency output X10
The delay time set is considered when the position at the instant of touch probe is determined (instant of zero
pulse) and serves to compensate dead times, if existent.
Setting range
(min. value | unit | max. value) Lenze setting
0 μs 7000 0 μs
; Read access ; Write access CINH PLC-STOP No transfer
Parameter | Name:
C14070 | Speed at DFOUT
Data type: INTEGER_32
Index: 10505
d
= 2909
h
Digital frequency extension module in module receptacle MXI2:
Display of the current speed at digital frequency output X10
Display range
(min. value | unit | max. value)
-2147483648 Incr./ms 2147483647
; Read access Write access CINH PLC-STOP No transfer
Parameter | Name:
C14071 | Frequency at DFOUT
Data type: INTEGER_32
Index: 10504
d
= 2908
h
Digital frequency extension module in module receptacle MXI2:
Display of the current frequency at digital frequency output X10
Display range
(min. value | unit | max. value)
-2147483648 Hz 2147483647
; Read access Write access CINH PLC-STOP No transfer
Parameter | Name:
C14072 | Position at DFOUT
Data type: INTEGER_32
Index: 10503
d
= 2907
h
Digital frequency extension module in module receptacle MXI2:
Display of the current position at digital frequency output X10
Display range
(min. value | unit | max. value)
-2147483648 Incr. 2147483647