Digital frequency extension module | Parameter setting & configuration
Parameter reference
Parameter list | C14015
40 L EDS94AYFLF EN 3.2 - 10/2010
C14015
C14021
C14030
C14031
C14032
C14035
Parameter | Name:
C14015 | Encoder mounting dir. (DFIN)
Data type: UNSIGNED_32
Index: 10560
d
= 2940
h
Selection list (Lenze setting in bold) Info
0 Clockwise direction of rotation
1 Counter-clockwise direction of
rotation
; Read access ; Write access ; CINH PLC-STOP No transfer
Parameter | Name:
C14021 | TP delay time DFIN
Data type: UNSIGNED_32
Index: 10554
d
= 293A
h
Digital frequency extension module in module receptacle MXI2:
Touch probe delay for digital frequency input X9
• The delay time set is considered when the position at the instant of touch probe is determined (instant of zero
pulse) and serves to compensate dead times, if existent.
Setting range
(min. value | unit | max. value) Lenze setting
0 μs 7000 0 μs
; Read access ; Write access CINH PLC-STOP No transfer
Parameter | Name:
C14030 | Speed at DFIN
Data type: INTEGER_32
Index: 10545
d
= 2931
h
Digital frequency extension module in module receptacle MXI2:
Display of the current speed at digital frequency input X9
Display range
(min. value | unit | max. value)
-2147483648 Incr./ms 2147483647
; Read access Write access CINH PLC-STOP No transfer
Parameter | Name:
C14031 | Frequency at DFIN
Data type: INTEGER_32
Index: 10544
d
= 2930
h
Digital frequency extension module in module receptacle MXI2:
Display of the current frequency at digital frequency input X9
Display range
(min. value | unit | max. value)
-2147483648 Hz 2147483647
; Read access Write access CINH PLC-STOP No transfer
Parameter | Name:
C14032 | Position at DFIN
Data type: INTEGER_32
Index: 10543
d
= 292F
h
Digital frequency extension module in module receptacle MXI2:
Display of the current position at digital frequency input X9
Display range
(min. value | unit | max. value)
-2147483648 Incr. 2147483647
; Read access Write access CINH PLC-STOP No transfer
Parameter | Name:
C14035 | Unit
Data type: VISIBLE_STRING
Index: 10540
d
= 292C
h
Subcodes Info
C14035/1 Unit for the position
C14035/2 Unit for the speed
; Read access Write access CINH PLC-STOP No transfer